uxrb130p65 monoblock® series uxrb130p65 integrated x-ray tube and control electronics in one compact assembly standard rs-232 digital interface offers access to diagnostics and operating logs standard windows test gui 7 micron focal spot for narrow beam 8 micron focal spot for wide beam 10mm/14mm spot to window spacing provides high geometric magnification 130kv @ 65w x-ray source spellman’s μxrb130p65 microfocus monoblock® x-ray sources are designed for high resolution imaging applications powering its internal microfocus x-ray tube up to 130kv @ 65w. features like 24vdc input voltage, small package size and standard rs-232 digital interface simplify integrating the μxrb130p65 into your x-ray system. the small, round focal spot size, optimized over the range of operating voltage, and high magnification, combined with stable high intensity output provides distortion free, superior quality 2d and 3d images. typical applications industrial x-ray: circuit board and electronic component inspection high resolution non destructive testing of metal and plastic parts micro ct for industrial applications battery inspection medical x-ray: micro ct for life sciences applications (ref. 128082-001 rev. e) narrow beam benefits (standard):the small round spot is optimized over the range of kv and power to provide distortion free images. operated at 4 watts yields a 6 micron spot for high resolution imaging. the 14mm spot to window spacing offers high geometric magnification. narrow beam x-ray characteristics (standard):spot ellipticity:±20% @ 16 watts, 130kv (either axis referred to average)beam geometry:≥ 53°, round beam, uniform beam profile in any directionspot to window spacing:14mm ±0.5mmwindow diameter ≈19mmwindow material and thickness:beryllium, 0.25mmtarget material:tungsten wide beam benefits (wb option):the 115 degree round beam is well suited for automatedinspection where a large field of view is required for maximum throughput or off angled views. the 10mm spot to window spacing provides superior high geometricmagnification.wide beam x-ray characteristics (wb option):voltage measured across the x-ray tube is within ±2% of the programmed valuespot ellipticity:±20% @ 16 watts, 130kv (either axis referred to average)cone of illumination:115°, round beam, uniform beam profile in any directionspot to window spacing:10mm ±0.5mmwindow diameter (uncollimated):≈38mmwindow material and thickness:beryllium, 0.51mmtarget material:tungsten input voltage:+24-27vdc input current:<6 amps anode supply:output voltage:20kv to 130kv (referenced to cathode gun supply)output current:up to 0.5ma, from 20kv to 130kv cooling:internal fan is incorporated. adequate air circulation around unit must be provided. weight:standard: 30lbs. (13.60kg) standard/extended tube: 34lbs. (15.40kg) light weight (lw option): 23lbs. (10.43kg) light weight/extended tube: 27lbs. (12.24kg) regulatory approvals: compliant to eec emc directive. compliant to eec low voltage directive options:wb: wide beamet: extended tube (wide beam only)lw: light weight spot table parameternarrow beamwide beam operating voltage range 45-130kv 50-130kv maximum power 65w, 130kv 65w, 130kv maximum beam current 0.500ma 0.500ma spot size 4 watt ≤ 7μ, 45-130kv ≤ 8μ, 50-130kv spot size 8 watt ≤ 10μ, 45-130kv ≤ 14μ, 50-130kv spot size 16 watt ≤ 22μ, 45-130kv ≤ 24μ, 50-130kv spot size 32 watt ≤ 48μ, 70-130kv ≤ 48μ, 70-130kv spot size 40 watt ≤ 60μ, 80-130kv ≤ 60μ, 80-130kv spot size 65 watt ≤ 100μ, 130kv ≤ 100μ, 130kv how to order: standard (narrow beam) part no.: μxrb130p65nb wide beam option part no.: μxrb130p65wb wide beam option and extension tube part no.: μxrb130p65wbet typical applications: micro ct non-destructive testing battery inspection pcb inspection
xrb011 monoblock® series xrb011 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight can be mounted in any physical orientation analog or digital control interface 80kv, 20-50w x-ray source spellman’s xrb011 series of monoblock® x-ray sources are designed for oem applications powering its internal x-ray tube up to 80kv at 20w and 80kv at 50w. features like 24vdc input voltage, small package size, standard analog interface and rs-232/ethernet digital interface simplify integrating the xrb011 into your x-ray system. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability and performance. typical applications: medical x-ray: fluoroscopy and radiography for extremities, specimen radiography. pulsed fluoroscopy (contact spellman sales) industrial x-ray: component inspection and non-destructive testing (ref. 128090-001 rev. af) x-ray characteristics: tube type:micro focus tube focal spot:33µm nominal, 50µm max. (iec 336) beam filter:ultem 0.060. (1.5mm)oil 0.175. (4.4mm) beam geometry:symmetrical 40° cone input voltage: 20w:24vdc ±1v @ 2.5a 50w:24vdc ±1v @ 4a x-ray tube voltage:nominal x-ray tube voltage is adjustable between 35kv to 80kv x-ray tube current: 20w:0-250µa over specified tube voltage range 50w:0-700µa over specified tube voltage range x-ray tube power:20/50w, maximum continuous voltage regulation: line:±0.5% for a ±1v change of nominal input line voltage load:±0.1% for a load change of 25µa to maximum rated current voltage accuracy:voltage measured across the x-ray tube is within ±1% of the programmed value voltage risetime:ramp time shall be =250ms from 10% to 90% of maximum rated output voltage voltage temperature coefficient:≤100ppm/°c over temperature fault:indicates that the internal oil temperature has exceeded 65° c. the high voltage output will be disabled. toggling the x-ray on command off and on will reset the fault. over voltage fault:an overvoltage (ov) fault is detected when the output voltage exceeds 82kv. the high voltage output will be disabled. toggling the x-ray on command off and on will reset the fault. voltage ripple:1% peak to peak current regulation: line:±0.5% for a ±1v change of nominal input line voltage load:±0.5% for a voltage change of 35kv to 80kv current accuracy:current measured through the x-ray tube is within ±2.5% of the programmed value over current fault:an overcurrent (oc) fault is detected when the emission current exceeds 275µa (20w model) and 710µa (50w model). toggling the x-ray on command off and on will reset the fault. arc intervention:one arc fault. the high voltage output will be disabled. toggling the x-ray on command off and on will reset the fault. filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb100n100 monoblock® series xrb100n100 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight universal input, power factor corrected with internal emi filter can be mounted in any physical orientation analog control interface and standard rs-232 digital interface *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. 100kv, 100w x-ray source spellman’s xrb100n100 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 100kv at 100w. features like universal input, small package size and a standard analog and rs-232 digital interface simplify integrating this monoblock® into your x-ray system. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: food inspection fill level confirmation security applications (ref. 128072-001 rev. l) x-ray characteristics: tube type:stationary anode, tungsten target focal spot:0.5mm (iec 336) beam filter: lexan:3.2mm oil:10mm ±0.1mm glass:1.8mm max beam geometry:symmetrical fan 74° x 10° ±1° input voltage:power factor corrected input 0.98, 100-240vac ±10%50/60hz, 2a, maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable between40kv to 100kv x-ray tube current:100ua to 1ma over specified tube voltage range x-ray tube power:100w, maximum continuous voltage regulation: line:±0.1% of maximum output voltage over a±10% change of nominal input line voltage load:±0.1% of maximum rated voltage for 100ua to 1ma load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime:ramp time shall be 1 second from 10% to 90% of maximum rated output voltage voltage overshoot:5% of maximum voltage, to return within 2.5% of maximum voltage in less than 50ms voltage ripple:0.5% peak to peak of maximum voltage for frequencies≤1khz emission current parameters current regulation: line:±0.5% of rated output current over a±10% change of nominal input line voltage load:±0.5% of rated output current for a change from 50% to 100% of rated output voltage current accuracy:current measured through the x-ray tube is within ±1% of the programmed value current risetime:ramp time shall be 1 second from 10% to 90% of maximum rated current arc intervention:3 arcs in 10 seconds with a 200ms quench = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb80n100 monoblock® xrb80n100 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight universal input, power factor corrected with internal emi filter can be mounted in any physical orientation analog control interface and standard rs-232 digital interface 80kv, 100w x-ray source spellman’s xrb80n100 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 80kv at 100w. features like universal input, small package size and a standard analog and rs-232 digital interface simplify integrating this unit into your x-ray system. the xrb80n100 is available either with fan shaped (standard) or (optional) cone shaped beam geometries. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical xrb80n100 monoblock® integrated x-ray source applications: x-ray scanning: bone densitometry thickness measurement food inspection fill level confirmation parcel inspection (ref. 128065-001 rev. y) x-ray characteristics: focal spot:0.5mm (iec 336) beam filter: ultem:3.30mm ±0.15mm oil:8mm ±0.1mm glass:1.8mm ±0.25mm be:0.8mm beam geometry: fan:standard. the beam angular coverage will be 75° with the beam plane perpendicular to the x-ray tube axis and 13° wide. cone:optional. 25° cone beam input voltage:power factor corrected input 0.98, 100-240vac ±10%50/60hz, 2a, maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable up to 80kv x-ray tube current:150ua to 1.25ma over specified tube voltage range x-ray tube power:100w, maximum continuous voltage regulation: line:±0.05% of maximum output voltage over a ±10% change of nominal input line voltage load:±0.1% of maximum rated voltage for 150ua to 1.25ma load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime: standard:ramp time shall be 500ms from 10% to90% of maximum rated output voltage optional:5 seconds. specify at time of order voltage overshoot:5% of maximum voltage, to return within 2.5% ofmaximum voltage in less than 100ms voltage ripple:1% peak to peak of maximum voltage forfrequencies≤1khzemission current parameters current regulation: line:±0.05% of rated output current over a ±10% change of nominal input line voltage load:±0.1% of rated output current for a change from 50% to 100% of rated output voltage current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime: standard:ramp time shall be 500ms from 10% to 90% of maximum rated current optional:5 seconds. specify at time of order arc intervention:3 arcs in 10 seconds with a 200ms quench = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb80pn100hr monoblock® series xrb80pn100hr integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight universal input, power factor corrected with internal emi filter can be mounted in any physical orientation analog monitoring interface and standard rs-232 digital program and monitor interface data logging and firmware controlled x-ray tube seasoning (smart controller option only) 80kv, 100w integrated x-ray source spellman’s xrb80pn100hr (high reliability) monoblock® x-ray source is designed for oem applications powering its internal bipolar x-ray tube up to 80kv at 100w. features like universal input, small package size and a standard rs-232 digital interface simplify integrating this monoblock® into your x-ray system. the xrb80pn100hr is available either with fan shaped (standard) or (optional) cone shaped beam geometries. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. the xrb80pn100hr is designed for long field life and comes with a 3 year warranty. typical applications: x-ray scanning thickness measurement food inspection fill level confirmation parcel inspection (ref. 128118-001 rev. n) x-ray characteristics: focal spot:0.8mm (iec 336) standard0.5mm (iec 336) optional beam filter: ultem:3.00mm ±0.15mm oil:7.5mm ±0.25mm glass:1.7mm ±0.2mm be:0.8mm beam geometry: fan:standard. the beam angular coverage will be 80° with the beam plane perpendicular to the x-ray tube axis and 20° wide (with a 2° tolerance) cone:optional. 20° cone beam (with a 2° tolerance) input voltage:power factor corrected input 0.98, 100-240vac ±10% 50/60hz, 2a maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable 40kv (±20kv) to 80kv (±40kv) x-ray tube current:150ua to 2.00ma over specified tube voltage range (100w max.) x-ray tube power:100w, maximum continuous voltage regulation: line:±0.05% of maximum output voltage over a ±10% change of nominal input line voltage load:±0.1% of maximum rated voltage for 150ua to 2.00ma load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime: standard:ramp time shall be <500ms from 10% to 90% of maximum rated output voltage voltage ripple:0.5% peak to peak of maximum voltage for frequencies ≤1khzemission current parameters current regulation: line:±0.05% of rated output current over a ±10% change of nominal input line voltage load:±0.1% of rated output current for a change from 50% to 100% of rated output voltage current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime: standard:ramp time shall be <500ms from 10% to 90% of maximum rated current arc intervention:4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = shutdown filament configuration:internal ac filament drive with closed loop filament emission control analog monitoring interface:ground referenced 0 to 9vdc for all monitoring signals. how to order: standard: part no.: xrb80pn100hr cone beam option part no.: xrb80pn100hr/cb 0.5mm focal spot option part no.: xrb80pn100hr/.5mm 80° x 10° narrow fan beam option part no.: xrb80pn100hr/nf cable option: part no.: xrb*)pn100hr/ra smart controller option part no.: xrb80pn100hr/sc
xrbd monoblock® series xrbd compact & lightweight universal input, power factor corrected can be mounted in any physical orientation analog monitoring interface, standard rs-232 digital interface and ethernet data logging and firmware controlled x-ray tube seasoning 100w, 210w, 350w and 500w x-ray source spellman’s xrbd series of monoblock® x-ray sources are designed for oem applications powering their internal bipolar x-ray tube at 160kv at power levels of 100w,210w, 350w and 500w. features such as universal input, compact package size and a standard rs-232 digital interface simplify integration of any xrbd model into your x-raysystem. each xrbd model is available with fan shaped (standard) or cone shaped (optional) beam geometries. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications food inspection systems, fill level confirmation systems, security scanning systems, industrial ndt systems, thickness/plating measurement systems (ref. 128132-001 rev. l) options:cbcone beam.5mm beam filter:st-te, ra-se, ra-tesee page 4 for cable options. x-ray characteristics: focal spot:0.8mm (iec 336)0.5mm (iec 336) optional beam filter: ultem:1.50mm ±0.15mm oil:9.0mm ±0.25mm glass:1.7mm ±0.2mm be:0.8mm beam geometry: fan:standard. the beam angular coverage will be 80° with the beam plane perpendicular to the x-ray tube axis and 12° wide (with a 2° tolerance) cone:optional. 40° cone beam (with a 2° tolerance) input voltage:100-240vac, ±10%, 50/60 hertz, .98 power factor input current:100w @ 1.4a210w @ 2.8a350w @ 4.6a500w @ 6.6a x-ray tube voltage:see table. minimum kv for emission current 35kv x-ray tube current:see table. minimum emission current 150ua x-ray tube power:see table voltage regulation: line:±0.05% of maximum output voltage over a ±10% change of nominal input line voltage load:±0.1% of maximum rated voltage for 150ua to full rated load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime:standard ramp time shall be <500ms from 10% to 90% of maximum rated output voltage voltage ripple:0.5% peak to peak of maximum voltage for frequencies ≤1khzemission current parameters current regulation: line:±0.05% of rated output current over a ±10% change of nominal input line voltage load:±0.1% of rated output current for a change from 50% to 100% of rated output voltage current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime: standard:ramp time shall be <500ms from 10% to 90% of maximum rated current arc intervention:4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = shutdown filament configuration:internal ac filament drive with closed loop filament emission control model selection table modelmaximum voltagemaximum currentmaximum power xrbd160pn100 160kv 1ma 100 watts xrbd160pn210 160kv 2.1ma 210 watts xrbd160pn350 160kv 3.5ma 350 watts xrbd160pn500 160kv 4ma 500 watts
xrbhr monoblock® series xrbhr compact & lightweight universal input, power factor corrected can be mounted in any physical orientation analog monitoring interface, standard rs-232 digital interface and ethernet data logging and firmware controlled x-ray tube seasoning 100w, 210w, 350w and 500w x-ray source spellman’s xrbhr (high reliability) series of monoblock® x-ray sources are designed for oem applications powering their internal bipolar x-ray tube at 80kv and 100kv at power levels of 100w, 210w, 350w and 500w. features such as universal input, compact package size and a standard rs-232 digital interface simplify integration of any xrbhr model into your x-ray system. each xrbhr model is available with fan shaped (standard) or cone shaped (optional) beam geometries. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. the xrbhr series is designed for long field life and comes with a3 year warranty. typical applications food inspection systems, fill level confirmation systems, security scanning systems, industrial ndt systems, thickness/plating measurement systems (ref. 128132-001 rev. w) options:cbcone beam.5mm.5mm focal spot x-ray tubest-tesee cable optionsra-sesee cable optionsra-tesee cable options x-ray characteristics: focal spot:0.8mm (iec 336) standard0.5mm (iec 336) optional beam filter: ultem:1.50mm ±0.15mm oil:9.0mm ±0.25mm glass:1.7mm ±0.2mm be:0.8mm beam geometry: fan:standard. the beam angular coverage will be 80° with the beam plane perpendicular to the x-ray tube axis and 12° wide (with a 2° tolerance) cone:optional. 40° cone beam (with a 2° tolerance) input voltage:100-240vac, ±10%, 50/60 hertz, .98 power factor input current:100w @ 2a210w @ 4a350w @ 6a500w @ 8a x-ray tube voltage:see table. minimum kv for emission current 35kv x-ray tube current:see table. minimum emission current 150ua x-ray tube power:see table voltage regulation: line:±0.05% of maximum output voltage over a ±10% change of nominal input line voltage load:±0.1% of maximum rated voltage for 150ua to full rated load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime:standard ramp time shall be <500ms from 10% to 90% of maximum rated output voltage voltage ripple:0.5% peak to peak of maximum voltage for frequencies ≤1khzemission current parameters current regulation: line:±0.05% of rated output current over a ±10% change of nominal input line voltage load:±0.1% of rated output current for a change from 50% to 100% of rated output voltage current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime: standard:ramp time shall be <500ms from 10% to 90% of maximum rated current arc intervention:4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = shutdown filament configuration:internal ac filament drive with closed loop filament emission control
xrb180pn200 monoblock® xrb180pn200 180kv and 200w x-ray tube current: 0.5ma to 1.1ma focal spot 0.8 x 0.8mm nominal (iec60336) power factor corrected input to 0.98 100vac to 240vac, ±10% *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. spellman’s xrb180pn200 is an integrated x-ray source operating up to 180kv and 200w, providing oem users a compact plug-and-play monoblock for critical inspection and screening applications. the unit incorporates a 25° angle stationary anode x-ray tube offering a fan beam of 80°x 4°. proprietary emission control circuitry provides excellent regulation of x-ray tube current, with industry leading dose stability and image quality. this compact model comes with standard analog and rs-232 digital control. spellman can provide customized versions of this platform for specific oem system requirements. typical applications aviation security screening: checked baggage/eds, checkpoint vehicle inspection, general ndt, food inspection (ref. 128085-001 rev. a) x-ray characteristics: tube type:stationary anode, tungsten target focal spot:0.8 x 0.8mm nominal (iec60336) beam filter:consists of oil and the curved ultem 0.079'' +/-0.01''. inherent filtration in the x-ray tube is 1mm be, 1.5mm +/-10% glass. beam geometry:fan of 80° x 4°, ±1% anode angle:25° input voltage:power factor corrected input to 0.98. 100vac to 240vac, ±10%, 50/60 hertz. 5a, maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable between 90kv to 180kv. voltage accuracy:the high voltage measured at the x-ray tube will be within ±1% of the selected value. voltage ripple:ripple will be ≤0.2% of maximum rated voltage for frequencies ≤1khz voltage regulation:< ±0.1% for ±10% of nominal input line change< ±0.1% for 0.5ma to 1.11ma load change voltage overshoot:kv overshoot will return within 5% of full voltage in less than 10ms risetime:the voltage and current risetime is controlled by a ramping circuit. ramp time is less than 0.5 second from 10% to 90% of output voltage and current. x-ray tube current:0.5ma to 1.1ma @ 180kv, 200 watts maximum current accuracy:<±1% of the selected value. current regulation:<0.5% at 90-180kv, 0.5ma to 1.1ma arc intervention:unit will detect a single arc but hv will not shut down. if multiple arcs occur (4 in 10 seconds) then the unit will shut down. filament configuration:internal high frequency ac filament drive operated in current mode with closed loop filament emission control.
xrb80pn320 monoblock® xrb80pn320 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight can be mounted in any physical orientation standard rs-232 digital interface 80kv, 320w x-ray source spellman’s xrb80pn320 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 80kv at 320w. features like small package size and rs-232 digital interface simplify integrating this monoblock® into your x-ray system. standard models are available with fan shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: food inspection fill level confirmation security applications (ref. 128091-001 rev. l) x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot options:0.8mm x 0.8mm (iec 336) beam filter:5052 al, 0.040" (±0.01") beam geometry:asymmetrical fan 80° x 10° ±2° input voltage:200-264vac, 50/60hz, 4.0a max x-ray tube voltage:nominal x-ray tube voltage is adjustable between 40kv to 80kv x-ray tube current:0.5ma to 4ma over specified tube voltage range x-ray tube power:320w maximum continuous voltage regulation: line:±0.05% for a ±10% input line change load:±0.05% for a 0.5ma to 4ma load change voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime:ramp time shall be <500ms from 10% to 90% of rated output voltage overshoot:within 5% of rated voltage in <10ms voltage ripple:≤1% p-p of rated voltage @ 1khz current regulation: line:±0.5% @ 50-100% v nominal over specified line range load:±0.5% @ 50-100% v nominal over specified load range current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime:<500ms from 10% to 90% of rated output arc intervention:4 arcs in 10 seconds = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb200pn400 monoblock® xrb200pn400 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight universal input, power factor corrected can be mounted in any physical orientation analog monitoring and standard rs-232 digital interface spellman’s xrb200pn400 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 200kv at 400w. features like universal input, small package size, standard analog monitoring and rs-232 digital interface simplify integrating this unit into your x-ray system. standard models are available with fan shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: food inspection fill level confirmation security applications (ref. 128085-001 rev. h) x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot:0.8mm x 0.5mm (iec336) beam filter:glass 1.8mm, oil 10mm, aluminum 1mm beam geometry:symmetrical fan 85° x 10° ±1° input voltage:100vac-240vac ±10%, 50/60hz, 6a maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable between 100kv to 200kv x-ray tube current:0.5ma to 2ma over specified tube voltage range x-ray tube power:400w maximum continuous (350w average without external forced air) voltage regulation: line:±0.1% for a ±10% input line change load:±0.1% for a 0.5ma to 2ma load change voltage accuracy:voltage measured across the x-ray tube is within ±1% of the programmed value voltage risetime:<1 second from 10% to 90% of rated output voltage overshoot:5% in less than 100ms voltage ripple:≤0.2% p p of rated maximum voltage current regulation: line:±0.1% @ 100-200kv, 0.25ma to 2ma load:±0.5% @ 100-200kv, 0.25ma to 2ma current accuracy:current measured through the x-ray tube is within ±1% of the programmed value current risetime:<1 second from 10% to 90% of rated output arc intervention:4 arcs in 10 seconds = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control digital interface:rs-232 interface. control software:a demo gui for engineering evaluations will be provided for the rs-232 digital interface upon request. interlock signals:a hardware interlock function is provided operating temperature:0°c to +40°c storage temperature:-40°c to +70°c humidity:5% to 95% relative humidity, non-condensing cooling:heat exchanger w/fan and oil pump, powered from 24vdc, 2a power supply (customer provided). external forced air cooling if needed to keep oil temperature below 55°c input line connector:3 pin phoenix contact 1829167
xrb200pn400/2 monoblock® xrb200pn400/2 200kv and 400w x-ray tube current: 0.5ma to 2.0ma @ 200kv symmetrical fan beam of 85° x 4°, ±1% power factor corrected input to 0.98 100vac to 240vac, ±10% logging and firmware controlled x-ray tube seasoning *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. spellman’s xrb200pn400/2 is an integrated x-ray source operating up to 200kv and 400w, providing oem users a compact plug-and-play monoblock® for critical inspection and screening applications. the unit incorporates a 15° angle stationary anode x-ray tube offering a symmetrical fan beam of 85° x 4°. proprietary emission control circuitry provides excellent regulation of x-ray tube current, with industry leading dose stability and image quality. this compact model comes with standard analog and rs-232 digital control. spellman can provide customized versions of this platform for specific oem system requirements. typical applications aviation security screening: checked baggage/eds vehicle inspection, cargo inspection, general ndt (ref. 128085-001 rev. b) x-ray characteristics: tube type:stationary anode, tungsten target focal spot:0.8 x 0.8mm nominal (iec60336) beam filter:glass 2.1mm, maximum. oil 18mm. beam geometry:symmetrical fan of 85° x 4°, ±1% anode angle:15° input voltage:power factor corrected input to 0.98. 100vac to 240vac, ±10%, 50/60 hertz. 6 amps, maximum x-ray tube voltage:nominal x-ray tube voltage is adjustable between 100kv to 200kv voltage accuracy:the high voltage measured at the x-ray tube will be within ±1% of the selected value. voltage ripple:ripple will be 1% of maximum rated voltage for frequencies ≤1khz. voltage regulation:< ±0.1% for ±10% of nominal input line change< ±0.1% for 0.5ma to 2ma load change voltage overshoot:kv overshoot will return within 5% of full voltage in less than 100ms. risetime:the voltage and current risetime is controlled by a ramping circuit. ramp time is less than 1.0 second from 10% to 90% of output voltage and current. x-ray tube current:0.5ma to 2.0ma @ 200kv, 400 watts maximum current accuracy:<±1% of the selected value. current regulation:<0.5% at 100 - 200 kv, 0.5ma to 2.0ma arc intervention:unit will detect a single arc but hv will not shut down. if multiple arcs occur (4 in 10 seconds) then the unit will shut down. filament configuration:isolated high frequency ac filament drive operated in current mode with closed loop thermionic filament emission control. digital interface:the rs-232 and ethernet interfaces allow for programming of the voltage, current and x-ray enable. provides monitoring for voltage, current and oil temperature. tolerance is 3%. control software:a demo gui is available for engineering evaluation. operating temperature:0°c to +40°c storage temperature:-40°c to +70°c humidity:10% to 95% relative humidity, non-condensing. cooling:heat exchanger with fan and oil pump. customer provided +24vdc @ 3a is required. in certain situations, external cooling fans of 250cfm may be required to maintain tank/oil temperature below 55°c. input line connector:3 pin phoenix contact, p/n 1829167. mating connector provided with unit.
xrb160pn480/1 monoblock® xrb160pn480/1 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight power factor corrected with internal emi filter can be mounted in any physical orientation analog monitoring and standard rs-232 digital interface 160kv, 480w x-ray source spellman’s xrb160pn480/1 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 160kv at 480w. features like power factor correction, small package size, standard analog monitoring and rs-232 digital interface simplify integrating this monoblock® into your x-ray system. standard models are available with fan shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications x-ray scanning: food inspection fill level confirmation security applications x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot:0.8mm x 0.8mm (iec336) beam filter:curved 1mm a beam geometry:asymmetrical fan 80° x 10° ±2° input voltage:220vac, ±10%, 50/60hz, 6.5a max x-ray tube voltage:nominal x-ray tube voltage is adjustable between 80kv to 160kv x-ray tube current:0.25ma to 3ma over specified tube voltage range x-ray tube power:500w, maximum continuous voltage regulation: line:±0.1% for a ±10% input line change of nominal input line voltage load:±0.1% for a 0.25ma to 3ma load change voltage accuracy:voltage measured across the x-ray tube is within ±2% plus 1.785kv of the programmed value voltage risetime:ramp time shall be =2 seconds from 10% to 90% of rated output voltage overshoot:±1% switching between 90kv to 160kv @ 0.25ma voltage ripple:≤0.1% of rated voltage from 10hz to 1khz current regulation: line:±0.5% @ 80-160kv, 0.25ma to 3ma load:±0.5%, 0.25ma to 3ma current accuracy:current measured through the x-ray tube is within 2% of the programmed value current risetime:≤2 seconds from 10% to 90% of rated output arc intervention:4 arcs in 10 seconds = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb160pn480/2 monoblock® xrb160pn480/2 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight universal input, power factor corrected can be mounted in any physical orientation analog control interface and standard rs-232 digital interface *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. 160kv, 480w x-ray source spellman’s xrb160pn480/2 monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 160kv at 480w. features like universal input, small package size and a standard analog and rs-232 digital interface simplify integrating this monoblock® into your x-ray system. standard models are available with fan shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: food inspection fill level confirmation security applications (ref. 128087-001 rev. j) x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot:0.8mm x 0.8mm (iec336) beam filter:1mm curved window beam geometry:asymmetrical fan 80° x 10° ±2° input voltage:100-240vac ±10%, 50/60hz, 6.5a max; 12vdc @ 5a x-ray tube voltage:nominal x-ray tube voltage is adjustable between80kv to 160kv x-ray tube current:0.25ma to 3ma over specified tube voltage range x-ray tube power:500w, maximum voltage regulation: line:±0.1% for a ±10% input line change of nominal input line voltage load:±0.1% for a 0.3ma to 3ma load change voltage accuracy:voltage measured across the x-ray tube is within ±1% of the programmed value voltage risetime:ramp time shall be <1 second from 10% to 90% of rated output voltage overshoot:within 5% of rated voltage in <10ms voltage ripple:0.1% p p of rated voltage @ ≤1khz current regulation: line:±0.1% for a ±10% input line change of nominal input line voltage load:±0.5% @ 80-160kv, 0.3ma to 3ma current accuracy:current measured through the x-ray tube is within ±1% of the programmed value current risetime:<1 second from 10% to 90% of rated output arc intervention:4 arcs in 10 seconds with a 200ms quench = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
xrb160pn480/ct monoblock® industrial x-ray generators xrb160pn480/ct integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight can be mounted in any physical orientation standard rs-232 digital interface *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. 160kv, 480w x-ray source spellman’s xrb160pn480/ct monoblock® x-ray source is designed for oem applications powering its internal x-ray tube up to 160kv at 480w. features like smallpackage size and rs-232 digital interface simplify integrating this monoblock® into your x-ray system. standard models are available with fan shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: food inspection fill level confirmation security applications (ref. 128083-001 rev. j) x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot:0.8mm x 0.8mm (iec336) beam filter:1.75mm of glass, 1mm of al, and 10mm of oil beam geometry:symmetrical fan 105° ±3° x 4° ±1° input voltage: monoblock®:100-240vac ±10%, 50/60hz, 6.5a max heat dissipation unit:24vdc, 3a x-ray tube voltage:nominal x-ray tube voltage is adjustable between 20kv to 160kv x-ray tube current:0.3ma to 6ma over specified tube voltage range x-ray tube power:320w continuous, 480w peak voltage regulation: line:±0.1% for a ±10% input line change of nominal input line voltage load:±0.1% for a 0.3ma to 6ma load change voltage accuracy:voltage measured across the x-ray tube is within ±1% of the programmed value voltage risetime:ramp time shall be <1 second from 1% to 90% of rated output voltage overshoot:within 5% of rated voltage voltage ripple:0.1% p p of rated voltage @ ≤1khz current regulation: line:±0.5% load:±0.5% current accuracy:current measured through the x-ray tube is within ±1% of the programmed value current risetime:<1 second from 1% to 90% of rated output arc intervention:4 arcs in 10 seconds = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control digital interface:rs-232 control software:a demo gui for engineering evaluations will be provided for the rs-232 digital interface upon request. interlock signals:a hardware interlock functions in digital programming modes. operating temperature:0°c to +40°c storage temperature:-40°c to +70°c humidity:5% to 90% relative humidity, non-condensing cooling:heat exchanger w/fan and oil pump, powered from ac input line connector:
xrb150pn600 monoblock® xrb150pn600 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight power factor corrected can be mounted in any physical orientation analog monitoring and standard rs-232 digital interface 150kv, 600w x-ray source spellman’s xrb150pn600 monoblock® x-ray source is designed for oem applications powering its internalx-ray tube up to 150kv at 600w. features like power factor correction, small package size and a standard analog and rs-232 digital interface simplify integrating this unit into your x-ray system. standard models are available with cone shaped beam geometry. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability performance. typical applications: x-ray scanning: bone densitometry food inspection security (ref. 128079-001 rev. g) x-ray characteristics: tube type:glass tube, tungsten target, be filter focal spot:0.5mm x 0.5mm(iec 336) beam filter:0.06. ultem beam geometry:cone up to 18° ±1° input voltage:vac, 50/60hz, 6.5a maximum 200-240 +/-10% x-ray tube voltage:nominal x-ray tube voltage is adjustable between 70kv to 150kv x-ray tube current:1.0ma to 4.0ma over specified tube voltage range x-ray tube power: 160w continuous, 600w peak duty cycle:30 seconds on, 300 seconds off @ 600w peak voltage regulation: line:±0.1% for a ±10% input line change of 180 to 264vac load:±0.1% for a 1.0ma to 4.0ma load change. 600w maximum voltage accuracy:voltage measured across the x-ray tube is within ±2% of the programmed value voltage risetime:±1% in less than 300ms voltage overshoot:±10% during 300ms risetime voltage ripple:1% rms of rated voltage @ 10hz to 1mhz current regulation: line:±0.1% from 180-264vac load:±0.5% @ 70-150kv, 1.0ma to 4.0ma current accuracy:current measured through the x-ray tube is within ±2% of the programmed value current risetime:±1% in less than 300ms arc intervention:4 arcs in 10 seconds with a 200ms quench = shutdown filament configuration:internal high frequency ac filament drive with closed loop filament emission control
pdm90pn900 monoblock® pdm x-ray source with integrated filament, tube and beam port separate control electronics box compact & lightweight analog or digital control interface spellman’s new panoramic dental monoblock® consists of an integrated x-ray tube, dual-output high voltage power supply, and filament supply with control circuitry. the pdm90pn900 is designed for extra oral dental x-ray applications including ct and panoramic x-ray. features like small package size, standard analog and rs-232digital interface simplify integrating this monoblock® into your x-ray system. proprietary emission control circuitry provides excellent regulation of x-ray tube current, along with outstanding stability and performance. typical applications: dental x-ray: panoramic and ct imaging (ref. 128109-001 rev. d) x-ray tube characteristics:target angle:5 degreesfocal spot:0.5mm nominalbeam filtration:3.0mm of al equivalent x-ray tube voltage:nominal x-ray tube voltage is adjustable between50kv to 90kv voltage regulation:line:±0.5% for a ±1v change of nominal input line voltageload:±0.1% for a load change of 25µa to maximum rated current x-ray tube current:1ma to 10ma over specified tube voltage range current regulation:line:±0.5% for a ±1v change of nominal input line voltageload:±0.5% for a voltage change of 35kv to 80kv x-ray tube power:900 watts peak power duty cycle:ct (pulsed):≤ 45 seconds scan time cycle at up to 40 pulses per second availablepanoramic (continuous):maximum scan time = 30s, with 60s off-time. five consecutive scans input voltage:100-240vac ±10% 50/60 hz, 10 amps rms maximum interface:the rs-232 serial communications interface will be used to program and monitor output voltage and current, control various functions and report status and faults. digital interface connector:rs-232:9 pin d connector, male operating temperature:0°c to +40°c storage temperature:-20°c to +70°c humidity:5% to 95% relative humidity, non-condensing cooling:tank:convectioncontroller:forced air via provided fan dimensions:x-ray tank:9.7"w x 7.7"h x 4.7"d (247mm x 195mm x 119mm)inverter/controller:7.10"w x 9.80"h x 3.60"d (180mm x 250mm x 92mm) weight:x-ray tank:17lbs (7.7kg)inverter/controller:6.5lbs (3kg) x-ray leakage:less than 100mr/hour (or <1mgy/hr) @ 1meter from the monoblock® surface. regulatory approvals:compliant to emc 60601-1-2 (external emc filter and shielding required). ul/cul recognized file e242584.
mmb125pn3.5 monoblock® mmb125pn3.5 integrated hv supply, filament supply, x-ray tube, beam port and control electronics compact & lightweight <1ms rise time is ideal for extremities specifically designed for the c-arm oem spellman’s mmb125pn3.5 medical monoblock® with <1ms rise time is ideal for extremities, specialized applications and vascular imaging. benefit from spellman’s 70 plus years of high voltage innovation with this mmb125pn3.5 monoblock® x-ray source specifically designed for the c-arm oem. our advanced technology and design expertise in conjunction with our depth of manufacturing capabilities position spellman as the wise choice for your monoblock® requirements. spellman’s ultra-fast mmb series utilizes our unique technologies that increases the quality of the x-ray beam and significantly reduces patient dose. pulsed fluoroscopy enhances imaging of dense and complex anatomy to further support dose management. with a rise time of <1ms, spellman’s mmb series is among the fastest in the industry. (ref. 128143-001 rev. a) x-ray characteristics:focal spot:0.5mm for small focus1.6mm for large focustarget angle: 16°target material: tungstenbeam filter: 0.8mm alx-ray leakage: less than <1mgy/hour @ 1meter from tank surface.maximum filament current:4.3afilament inverterswitching frequency:20khzanode heat content:35.5kjmaximum anodeheat dissipation:600wdistance betweenfocal spot to x-rayoutput window:45mm input power:input voltage:190-264vac, single phase, 50/60 hzcontinuous current:≤9a @ 600w, 220vpeak current:≤34a @ 3500w, 220v x-ray tube voltage:operational range:40 to 125kvkv rise time:<1ms (from 10% to 90%)reproducibility:≤0.05 per iec60601-2-54kv ripple:≤1%kv accuracyfluoroscopy:±5%kv overshoot:≤5% x-ray tube current:fluoro:0.2ma to 6 ma (small focal spot)pulsed fluoro:0.5ma to 10 ma (small focal spot)radiography:10ma to 40ma (large focal spot)ma accuracy:±10%maximum operating conditions:continuouslow level fluoro:6 ma for 5 minutescontinuoushigh level fluoro:10 ma for 2 minutespulsed fluoro:0.5fps, 1fps, 2fps, 4fps, 8fps, 15fps,25fps, 30fps for 2 minutespulse on time:the lower value of 40msor 50% duty cycleradiographic:single shot large focal spot,0.1 seconds @ 3500 wattsmaximum anodeheat dissipation:600waverage power:600w for 5 minutestank heat content:no less than 675khumax. cooling rate:150w x-ray tube current protection:over current (high ma):trip point is set at 15% over maximum rated current, or at 15% over programmed output current value for longer than 50ms.under current (high ma):trip point is set at 15% under programmed output current value for longer than 50ms.over current (low ma):trip point is set at 20% over maximum rated current, or at 20% over programmed output current value for longer than 50ms.under current (low ma):trip point is set at 20% under programmed output current value for longer than 50ms. x-ray tube voltage protection:over voltage (high kv):trip point is when the kv output exceeds 137.5kv for more than 10ms or it set is at 10% over programmed output voltage value for longer than 30ms.under voltage (low kv):trip point is set at 10% under the programmed output voltage value for longer than 30ms. x-ray tube arc protection:arc intervention:unit will detect an arc but hv will not be shut down, but if multiple arcs occur (4 arcs in 10 seconds) the unit will shut down. over temperature protection:over temperature:over temperature of tank cover trip point shall be within 60°c ±5°c. over temperature of tank oil trip point shall be set 65°c. operating temperature:0 to +40 ºc. storage temperature:-20 to +70 ºc altitude:0 to 8000 feet (0 to 2438 meters) humidity:5 to 95%, non-condensing. dimensions:x-ray tank:12.2” x 6.2” x 5.7” (310mm x 158mm x 145mm)controller:14.9” x 10.6” x 3.2” (380mm x 270mm x 83mm) weight:x-ray tank:27.5 pounds (13kg)controller:9.9 pounds (4.5kg) regulatory approvals:designed to be compliant to:iec 60601-1:2005+amedical electrical equipment part 1:general requirements for basic safety and essential performance.iec 60601-1-22007 medical electrical equipment part 1-2:general requirements for basic safety and essential performance- collateral standard: electromagnetic compatibility—requirements and tests.iec 60601-1-32008 medical electrical equipment part 1-3:general requirements for basic safety and essential performance- collateral standard: radiation protection in diagnostic x-ray equipment.iec 60601-2-542009 medical electrical equipment part 2:particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy.emcdesigned to meet iec requirements for medical components. (note:external emi filter may be required) rohscontroller and tank assembly are rohs compliant.