XRB160PN480/CT Monoblock® Industrial X-Ray Generators
- Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
- Compact & Lightweight
- Can be Mounted in Any Physical Orientation
- Standard RS-232 Digital Interface
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
Certifications & Compliance
160kV, 480W X-Ray Source
Spellman’s XRB160PN480/CT Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 480W. Features like smallpackage size and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.
Typical applications:
- X-Ray Scanning: Food Inspection
- Fill Level Confirmation
- Security Applications
- 사양
- 다운로드
사양
(Ref. 128083-001 REV. J)
- X-Ray Characteristics:
- Tube Type:
Glass tube, Tungsten target, Be filter - Focal Spot:
0.8mm x 0.8mm (IEC336) - Beam Filter:
1.75mm of glass, 1mm of Al, and 10mm of oil - Beam Geometry:
Symmetrical fan 105° ±3° x 4° ±1° - Input Voltage:
- Monoblock®:
100-240Vac ±10%, 50/60Hz, 6.5A max - Heat Dissipation Unit:
24Vdc, 3A - X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 20kV to 160kV - X-Ray Tube Current:
0.3mA to 6mA over specified tube voltage range - X-Ray Tube Power:
320W continuous, 480W peak - Voltage Regulation:
- Line:
±0.1% for a ±10% input line change of nominal input line voltage - Load:
±0.1% for a 0.3mA to 6mA load change - Voltage Accuracy:
Voltage measured across the X-Ray tube is within ±1% of the programmed value - Voltage Risetime:
Ramp time shall be <1 second from 1% to 90% of rated output - Voltage Overshoot:
Within 5% of rated voltage - Voltage Ripple:
0.1% p p of rated voltage @ ≤1kHz - Current Regulation:
- Line:
±0.5% - Load:
±0.5% - Current Accuracy:
Current measured through the X-Ray tube is within ±1% of the programmed value - Current Risetime:
<1 second from 1% to 90% of rated output - Arc Intervention:
4 arcs in 10 seconds = Shutdown - Filament Configuration:
Internal high frequency AC filament drive with closed loop filament emission control - Digital Interface:
RS-232 - Control Software:
A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request. - Interlock Signals:
A hardware interlock functions in digital programming modes. - Operating Temperature:
0°C to +40°C - Storage Temperature:
-40°C to +70°C - Humidity:
5% to 90% relative humidity, non-condensing - Cooling:
Heat exchanger w/fan and oil pump, powered from AC - Input Line Connector:
다운로드
스펠만 고전압 뉴스레터를 구독하세요