XRB200PN400 Monoblock®

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & Lightweight
  • Universal Input, Power Factor Corrected
  • Can be Mounted in Any Physical Orientation
  • Analog Monitoring and Standard RS-232 Digital Interface
견적 받기

Spellman’s XRB200PN400 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 200kV at 400W. Features like universal input, small package size, standard analog monitoring and RS-232 digital interface simplify integrating this unit into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

Typical applications:

  • X-Ray Scanning: Food Inspection
  • Fill Level Confirmation
  • Security Applications
  • 사양
  • 다운로드

사양

(Ref. 128085-001 REV. H)

  • X-Ray Characteristics:
  • Tube Type:
    Glass tube, Tungsten target, Be filter
  • Focal Spot:
    0.8mm X 0.5mm (IEC336)
  • Beam Filter:
    Glass 1.8mm, Oil 10mm, Aluminum 1mm
  • Beam Geometry:
    Symmetrical fan 85° x 10° ±1°
  • Input Voltage:
    100Vac-240Vac ±10%, 50/60Hz, 6A maximum
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable between 100kV to 200kV
  • X-Ray Tube Current:
    0.5mA to 2mA over specified tube voltage range
  • X-Ray Tube Power:
    400W maximum continuous (350W average without external forced air)
  • Voltage Regulation:
  • Line:
    ±0.1% for a ±10% input line change
  • Load:
    ±0.1% for a 0.5mA to 2mA load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±1% of the programmed value
  • Voltage Risetime:
    <1 second from 10% to 90% of rated output
  • Voltage Overshoot:
    5% in less than 100ms
  • Voltage Ripple:

    0.2% p p of rated maximum voltage
  • Current Regulation:
  • Line:
    ±0.1% @ 100-200kV, 0.25mA to 2mA
  • Load:
    ±0.5% @ 100-200kV, 0.25mA to 2mA
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±1% of the programmed value
  • Current Risetime:
    <1 second from 10% to 90% of rated output
  • Arc Intervention:
    4 arcs in 10 seconds = shutdown
  • Filament Configuration:
    Internal high frequency AC filament drive with closed loop filament emission control
  • Digital Interface:
    RS-232 interface.
  • Control Software:
    A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request.
  • Interlock Signals:
    A hardware interlock function is provided
  • Operating Temperature:
    0°C to +40°C
  • Storage Temperature:
    -40°C to +70°C
  • Humidity:
    5% to 95% relative humidity, non-condensing
  • Cooling:
    Heat exchanger w/fan and oil pump, powered from 24Vdc, 2A power supply (customer provided). External forced air cooling if needed to keep oil temperature below 55°C
  • Input Line Connector:
    3 pin Phoenix Contact 1829167