뒤로
다음 기준으로 제품 찾아보기:
응用 분야
뒤로
응용 분야별 제품 보기
모든 응용 분야 보기

XRB80PN100HR Monoblock® Series

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & Lightweight
  • Universal Input, Power Factor Corrected with Internal EMI Filter
  • Can be Mounted in Any Physical Orientation
  • Analog Monitoring Interface and Standard RS-232 Digital Program and Monitor Interface
  • Data Logging and Firmware Controlled X-Ray Tube Seasoning (Smart Controller Option Only)

Certifications & Compliance

견적 받기

80kV, 100W Integrated X-Ray Source

Spellman’s XRB80PN100HR (high reliability) Monoblock® X-Ray source is designed for OEM applications powering its internal Bipolar X-Ray tube up to 80kV at 100W. Features like universal input, small package size and a standard RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. The XRB80PN100HR is available either with fan shaped (standard) or (optional) cone shaped beam geometries. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance. The XRB80PN100HR is designed for long field life and comes with a 3 year warranty.

Typical applications:

  • X-Ray Scanning
  • Thickness Measurement
  • Food Inspection
  • Fill Level Confirmation
  • Parcel Inspection
  • 사양
  • 주문 방법
  • 다운로드

사양

(Ref. 128118-001 REV. N)

  • X-Ray Characteristics:
  • Focal Spot:
    0.8mm (IEC 336) standard
    0.5mm (IEC 336) optional
  • Beam Filter:
  • Ultem:
    3.00mm ±0.15mm
  • Oil:
    7.5mm ±0.25mm
  • Glass:
    1.7mm ±0.2mm
  • Be:
    0.8mm
  • Beam Geometry:
  • Fan:
    Standard. The beam angular coverage will be 80° with the beam plane perpendicular to the X-Ray tube axis and 20° wide (with a 2° tolerance)
  • Cone:
    Optional. 20° cone beam (with a 2° tolerance)
  • Input Voltage:
    Power factor corrected input 0.98, 100-240Vac ±10% 50/60Hz, 2A maximum
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable 40kV (±20kV) to 80kV (±40kV)
  • X-Ray Tube Current:
    150uA to 2.00mA over specified tube voltage range (100W max.)
  • X-Ray Tube Power:
    100W, maximum continuous
  • Voltage Regulation:
  • Line:
    ±0.05% of maximum output voltage over a ±10% change of nominal input line voltage
  • Load:
    ±0.1% of maximum rated voltage for 150uA to 2.00mA load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±2% of the programmed value
  • Voltage Risetime:
  • Standard:
    Ramp time shall be <500ms from 10% to 90% of maximum rated output voltage
  • Voltage Ripple:
    0.5% peak to peak of maximum voltage for frequencies ≤1kHz
    Emission Current Parameters
  • Current Regulation:
  • Line:
    ±0.05% of rated output current over a ±10% change of nominal input line voltage
  • Load:
    ±0.1% of rated output current for a change from 50% to 100% of rated output voltage
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±2% of the programmed value
  • Current Risetime:
  • Standard:
    Ramp time shall be <500ms from 10% to 90% of maximum rated current
  • Arc Intervention:
    4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = Shutdown
  • Filament Configuration:
    Internal AC filament drive with closed loop filament emission control
  • Analog Monitoring Interface:
    Ground referenced 0 to 9Vdc for all monitoring signals.

주문 방법

How to Order:
Standard: Part No.: XRB80PN100HR

Cone Beam Option

Part NO.: XRB80PN100HR/CB

0.5mm Focal Spot Option

Part NO.: XRB80PN100HR/.5mm

80° X 10° Narrow Fan Beam Option

Part NO.: XRB80PN100HR/NF

Cable Option:

Part NO.: XRB*)PN100HR/RA

 Smart Controller Option

Part NO.: XRB80PN100HR/SC