XRB180PN200 Monoblock®
- 180kV and 200W
- X-Ray Tube Current: 0.5mA to 1.1mA
- Focal Spot 0.8 x 0.8mm nominal (IEC60336)
- Power factor corrected input to 0.98
- 100Vac to 240Vac, ±10%
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
Spellman’s XRB180PN200 is an integrated X-Ray source operating up to 180kV and 200W, providing OEM users a compact plug-and-play Monoblock for critical inspection and screening applications. The unit incorporates a 25° angle stationary anode X-Ray tube offering a fan beam of 80°x 4°. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, with industry leading dose stability and image quality. This compact model comes with standard analog and RS-232 digital control. Spellman can provide customized versions of this platform for specific OEM system requirements.
TYPICAL APPLICATIONS
Aviation Security Screening: Checked Baggage/EDS, Checkpoint Vehicle Inspection, General NDT, Food Inspection
- 사양
- 다운로드
사양
(Ref. 128085-001 REV. A)
- X-Ray Characteristics:
- Tube Type:
Stationary Anode, tungsten target - Focal Spot:
0.8 x 0.8mm nominal (IEC60336) - Beam Filter:
Consists of oil and the curved Ultem 0.079'' +/-0.01''. Inherent filtration in the X-Ray Tube is 1mm Be, 1.5mm +/-10% glass. - Beam Geometry:
Fan of 80° X 4°, ±1% - Anode Angle:
25° - Input Voltage:
Power factor corrected input to 0.98. 100Vac to 240Vac, ±10%, 50/60 Hertz. 5A, maximum - X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 90kV to 180kV. - Voltage Accuracy:
The high voltage measured at the X-ray tube will be within ±1% of the selected value. - Voltage Ripple:
Ripple will be ≤0.2% of maximum rated voltage for frequencies ≤1kHz - Voltage Regulation:
< ±0.1% for ±10% of nominal input line change
< ±0.1% for 0.5mA to 1.11mA load change - Voltage Overshoot:
kV overshoot will return within 5% of full voltage in less than 10ms - Risetime:
The voltage and current risetime is controlled by a ramping circuit. Ramp time is less than 0.5 second from 10% to 90% of output voltage and current. - X-Ray Tube Current:
0.5mA to 1.1mA @ 180kV, 200 Watts maximum - Current Accuracy:
<±1% of the selected value. - Current Regulation:
<0.5% at 90-180kV, 0.5mA to 1.1mA - Arc Intervention:
Unit will detect a single arc but HV will not shut down. If multiple arcs occur (4 in 10 seconds) then the unit will shut down. - Filament Configuration:
Internal high frequency AC filament drive operated in current mode with closed loop filament emission control.
다운로드