xlg series xlg output voltages to 130kv ground referenced filament supply “hot anode”, positve polarity local & remote programming spellman’s xlg series of x-ray generators are well regulated high voltage power supplies with output voltages to 130kv and very low ripple achieved through the use of advanced resonant conversion techniques. extremely stable voltage and emission current outputs result in significant performance improvements over previously available technology. the xlg series provides all the power, control and support functions required for x-ray applications including a regulated dc filament supply. these units incorporate local and remote programming, monitoring, safety interlock, short-circuit and overload protection. (ref. 128012-001 rev. m) input voltage:115vac±10%, 50-60hz single phase or220vac±10%, 50-60hz single phase. filament:specify at time of order:fh: 9a, 3v.fl: 3a, 3v.preheat level is 0.45 amps in standby voltage regulation:load:0.005% of full output voltage no load to full load.line:0.005% for input voltage range change. current regulation:load:0.05% of full current ±100µa from 0 to full voltage.line:0.05% of rated current over specified input range. ripple:0.03% rms below 1khz.0.75% rms above 1khz. temperature coefficient:100ppm/°c. stability:0.01%/8 hrs after 1/2 hour warm-up.0.02% per 8 hours (typical). cooling:free air convection. dimensions:30 to 60kv: 3.5”h x 19”w x 19”d (8.9cm x 48.3cm x 48.3cm).80 to 130kv: 3.5”h x 19”w x 24”d (8.9cm x 48.3cm x 61.0cm). regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. xlg selection table 0.1ma, 0.2ma , 0.5ma kv0.1ma0.2ma.5ma 30 xlg30p3* xlg30p6* xlg30p15* 35 xlg35p3.5* xlg35p7* xlg35p17.5* 40 xlg40p4* xlg40p8* xlg40p20* 50 xlg50p5* xlg50p10* xlg50p25* 60 xlg60p6* xlg60p12* xlg60p30* 80 xlg80p8* xlg80p16* xlg80p40* 100 xlg100p10* xlg100p20* xlg100p50* 120 xlg120p12* xlg120p24* xlg120p60* 130 xlg130p13* xlg130p26* xlg130p65* *specify fh for high power (27w) filament, fl for low power (9w) filament. xlg selection table 1.0ma, 2.0ma, 3.0ma kv1.0ma2.0ma3.0ma 30 xlg30p30* xlg30p60* xlg30p90* 35 xlg35p35* xlg35p70* xlg35p105* 40 xlg40p40* xlg40p80* xlg40p120* 50 xlg50p50* xlg50p100* xlg50p150* 60 xlg60p60* xlg60p120* xlg60p180* 80 xlg80p80* xlg80p160* --- 100 xlg100p100* xlg100p200* --- 120 xlg120p120* xlg120p240* --- 130 xlg130p130* xlg130p260* --- *specify fh for high power (27w) filament, fl for low power (9w) filament. optionsapt - adjustable power tripat - arc tripss(x) - non-standard slow startnss - no slow startio - instant onll(x) - extra length hv cablesl - slides typical applications: analytical x-ray x-ray fluorescence plating measurement mineral analysis
xmpg xmpg output voltage 4kv to 10kv integrated ground referenced filament supply low ripple local and remote programming oem customization available 4kv - 10kv x-ray generator the xmpg is a modular 10kv @ 10w x-ray generator designed to drive a grounded filament x-ray tube via closed loop filamentary control of the 0 to 1ma emission current. the grounded filament supply is rated at 0-5 amps @ 3vdc. the filament supply features an internally adjustable 0.5 to 2.5 amp filament preheat and a internally adjustable 0 to 5 amp filament limit. the high voltage program and emission current program have internal preset capability simplify interfacing to this x-ray generator. or a customer provided 0 to 10vdc signal can be used to remotely control these two signals. a high voltage monitor signal and emission current monitor signal is provided. a high voltage enable input provides control of the high voltage output and a filament stable output indicates the filament current is stable and the x-ray tube is producing x-rays. typical applications: analytical x-raythickness gaugingx-ray fluorescence (ref. 128122-001 rev. b) input voltage:+24 vdc, ±10% input current:2 amp maximum output voltage:10kv, controllable over the range 4kv to 10kv polarity:positive voltage regulation:line:<0.01% for input voltage change of ±10%load:<0.01% for zero to full load voltage stability:< 0.1% per 24 hours at constant operating conditions, after 30 minutes warm up ripple:< 500mv p-p of output voltage at full load current regulation:line: ≤0.01% for 10% input voltage change under any load conditionsload: ≤0.01% for full load to short circuit emission current:0-1ma filament supply:voltage:0v to 3vdc referenced to groundload current:5a max, preset adjustable limitstability:< 0.25% per 8 hours at constant operating conditionsripple:<50mv p-p (at maximum load current). dimensions:1.31”h x 4.13”w x 7.28”d (33.5mm x 105mm x 185mm) weight:4.4 lbs. (2.0kg) regulatory approvals:compliant to eec low voltage directive. rohs compliant. how to order: model number: xmpg10p10/24 typical applications: analytical x-ray thickness gauging x-ray fluorescence
mfx series mfx 50kv at 2ma, 50 or 75 watt max 65kv at 2ma, 65 watt max floating integrated filament supply arc & short circuit protection voltage & current programming local and remote emission control safety interlock optional digital interface the mfx series is the result of spellman’s exceptional high voltage packaging and surface mount fabrication techniques, coupled with its proprietary encapsulation technology producing this ultra compact-sized oem x-ray generator module. the mfx series is designed to power floating filament x-ray tubes from various manufacturers. it features a 0 to 50kv (or 0 to 65kv) high voltage output, and up to 2ma of emission current limited to 50, 65 or 75 watts, operating from a +24vdc input. the mfx utilizes a closed loop filamentry beam control circuit to provide a highly regulated beam current. the floating ac filament supply operates between 0.3 and 4 amps. offering tight regulation, high stability and low ripple, the mfx provides users both local and remote analog control to set beam voltage, emission current and filament current limit. an optional usb, rs-232 and ethernet interface is available. optionssic standard interface controller (ethernet, usb & rs-232) 5vpm 0 to 5 volt programming and monitor scaling (ref. 128101-001 rev. k) input:+24vdc ±10%, 5.0a maximum for either 50 watts or 75 watts.+24vdc ±1v, 5.0a maximum for 65kv/65w units. output:0 to 50kv at 0 to 2ma, limited to a maximum of 50 watts or 75 watts.0-65kv at 2ma limited to 65 watts. negative output high frequency ac filament supply:current: 0-4a, adjustable limitvoltage: 5.0 volt limit voltage regulation:load: 0.01% of output voltage no load to full load.line: ±0.01% for ±10% change in input voltage.current regulation:load: 0.01% of output current from 0 to rated voltage.line: ±0.01% for ±10% change in input voltage. ripple:0.1% p-p of maximum rated output voltage, 50kv units (50/75w)0.1% rms maximum rated output voltage, 65kv units (65w) temperature coefficient:0.01% per °c, voltage and current. stability: 0.05% per 8 hours after 1/2 hour warm-up. weight: 7.0 lbs. (3.2kg) dimensions:50kv unit:7.00”h x 2.87”w x 8”d (177.80mm x 72.90mm x 203.25mm)65kv unit:7.00”h x 2.87”w x 9”d (177.80mm x 72.90mm x 228.65mm)sic option:7.75”h x 2.87”w x 8”d/9”d (196.85mm x 72.90mm x 203.25mm/228.65mm) weight:7.0 lbs. (3.2kg) regulatory approvals:rohs compliant. how to order: sample model number:50 watt unit: mfx50n5065 watt unit: mfx65n6575 watt unit: mfx50n75 options are added to the model number as follows:mfx50n75/sic typical applications: analytical x-ray x-ray diffraction thickness gauging
mnx series mnx 50kv at 50 or 75 watt max 65kv at 65 watt max adjustable integrated filament supply local and remote emission control ce marked, ul recognized 50-75w industrial x-ray generators the mnx series is the result of spellman’s exceptional high voltage packaging and surface mount fabrication techniques coupled with proprietary encapsulation technology producing this ultra-compact x-ray generator module. the mnx powers grounded cathode x-ray tubes from a variety of well-known manufacturers, featuring a 0 to 50kv/65kv high voltage output @ 2ma limited to 50, 65 or 75 watts. the mnx uses closed loop filament control circuitry providing highly regulated beam current. the ground referenced low noise dc filament supply operates between 0.3 and 3.5 amps. offering tight regulation, high stability and low ripple, the mnx provides users local and remote analog control to set beam voltage, emission current and filament current limit. the mnx is designed to run a variety of tubes from industry leading manufacturers. contact spellman sales to determine if the x-ray tube of interest can be powered by the mnx. (ref. 128023-001 rev. ae) input voltage:+24vdc ±10%, for 50w or 75w units+24vdc ±1v, for 65kv @ 65w unit input current:mnx50p50: 4.0 amps, maximum mnx50p75: 6.0 amps, maximum mnx65p65: 5.0 amps, maximum gb option: 1.0 amp additional, maximum output:0 to 50kv at 0 to 2ma, limited to a maximum of 50 watts or 75 watts.0-65kv at 2ma limited to 65 watts. dc filament supply:current: 3.5a, adjustable limitvoltage: 5.0 volt limitvoltage regulation: load: 0.01% of output voltage no load to full load. line: ±0.01% for ±10% change in input voltage. current regulation: load: 0.01% of output current from 0 to rated voltage. line: ±0.01% for ±10% change in input voltage. ripple: 0.1% p-p of maximum rated output voltage, 50kv units (50/75w) 0.1% rms maximum rated output voltage, 65kv units (65w) temperature coefficient: 0.01% per °c, voltage and current. stability: 0.05% per 8 hours after 1/2 hour warm-up. dimensions:50kv unit:5.00”h x 2.87”w x 8”d (127.00mm x 72.90mm x 203.25mm)65kv unit:5.00”h x 2.87”w x 9”d (127.00mm x 72.90mm x 228.65mm)xcc option:5.00”h x 2.87”w x 9”d (50/75w units only) (127.00mm x 72.90mm x 228.65mm) weight: 6.5 lbs. (2.9kg) regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. ul/cul recognized, file e227588; mnx65p65 is not ul/cul recognized. rohs compliant. mnx selection table modeloutput voltageoutput power mnx50p50 50kv 50w mnx65p65 65kv 65w mnx50p75 50kv 75w optiondescription xcc xrm compatible hv cable (50kv only) 5vpm 0 to 5 volt programming and monitor scaling 5302 mammoflex hv cable for mnx 2001 mammoflex hv cable for mnx w/xcc option how to order: sample model number:50 watt unit: mnx50p5065 watt unit: mnx65p6575 watt unit: mnx50p75 options are added to the model number as follows:mnx50p50/xcc typical applications: analytical x-ray x-ray fluorescence x-ray diffraction non-destructive testing thickness gauging tube testing
ux series ux 50kv with 50 or 75 watt max. 65kv with 65 watt max. adjustable isolated filament supply local and remote emission control rs-232, ethernet, & usb standard 50-75w industrial x-ray generators the ux series is the result of spellman’s exceptional high voltage packaging and surface mount fabrication techniques coupled with proprietary encapsulation technology producing this ultra-compact x-ray generator module. the ux powers grounded cathode x-ray tubes from a variety of well-known manufacturers, featuring a 0 to 50kv/65kv high voltage output @ 2ma limited to 50, 65 or 75 watts. the ux uses closed loop filament control circuitry providing highly regulated beam current. the low noise dc filament supply operates between 0.3 and 3.5 amps. offering tight regulation, high stability and low ripple, the ux provides users local and remote analog control to set beam voltage, emission current and filament current limit. usb, rs-232 and ethernet interface is standard. typical applications: the ux is designed to run a variety of tubes from industry leading manufacturers. contact spellman sales to determine if the x-ray tube of interest can be powered by the ux. options xcc xrm compatible hv cable (50kv only)5vpm 0 to 5 volt programming and monitor scalinggb grid biasgf grounded filament5302 mammoflex hv cable for ux2001 mammoflex hv cable for ux w/xcc option (ref. 128108-001 rev. l) input:+24vdc ±10%, 5.0a maximum for either 50 watts or 75 watts.+24vdc ±1v, 5.0a maximum for 65kv/65w units. efficiency:75%, typical output:0 to 50kv at 0 to 2ma, limited to a maximum of 50 wattsor 75 watts. 0-65kv at 2ma limited to 65 watts. dc filament supply:isolated filament power supply generates emission current feedback signal for accurate low x-ray tube current performance.current:3.5a, adjustable limitvoltage:5.0 volt limit temperature coefficient:0.01% per °c, voltage and current. stability:0.05% per 8 hours after 1/2 hour warm-up. dimensions:50kv unit:4.00"h x 2.87"w x 8.00"d (101.6mm x 72.95mm x 202.20mm).65kv unit:4.00â"h x 2.87"w x 9.00"d (101.6mm x 72.95mm x 228.60mm).xcc option:4.00"h x 2.87"w x 9.00"d (101.6mm x 72.95mm x 228.60mm). weight:4.5 lbs. (2.1kg) typical regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. rohs compliant. ul/cul recognized, file e227588 grid bias specificationsoutput voltage:0 to -300vdcoutput current:0.25ma, maximumload regulation:1% of output voltage, no load to full loadline regulation:1% for a ±10% change in input voltageripple:1% of maximum rated voltageux with grid bias option how to order: sample model number:50 watt unit: ux50p5065 watt unit: ux65p6575 watt unit: ux50p75 options are added to the model number as follows:ux50p50/xcc or ux50p75/gb typical applications: analytical x-ray x-ray fluorescence x-ray diffraction non-destructive testing thickness gauging tube testing
xrf series xrf 160kv output voltage rack-mountable floating filament (ac or dc) internal grid power supply (80w model) power factor correction closed-loop emission control oem customization/x number required 80-640w industrial x-ray generators spellman’s xrf x-ray generator platform allows for a wide range of input voltages and supply either 80w, 320w or 640w of output power at up to 160kvdc. these lightweight rack-mountable x-ray generators house a miniaturized high voltage system in a solid encapsulated, oil-free design. the xrf series x-ray generator is designed with a power factor corrected input circuit which reduces harmonic emissions and noise normally associated with other high frequency switching power supplies. the xrf series x-ray generator incorporates an internal floating filament and a closed-loop emission control circuit for precise regulation of emission current. remote monitoring and control of voltage, current and filament current is also provided. typical options df dual filamentgs grid supplysl slidesat arc tripio instant onss(x) non standard slow start (ref. 128013-001 rev. t) input voltage:80w:90-125vac at 48-62hz @ 1.9a180-264vac at 48-62hz @ 0.9a320w:180-264vac at 48-62hz @ 3.5a640w:180-264vac at 48-62hz @ 7a power factor:0.9 or better. high voltage supply:output voltage:0-160kv, negative polarity.output current:80w: 0.5ma max.320w: 2.0ma at 160kv 640w: 4.0ma.output voltage stability:within 0.1% of set value after warm-up period at full load.output voltage ripple:80w & 320w:<0.1%, or 160v p-p for high freq. and line freq. at full load.640w:0.03% rms <1khz, 0.75% rms above 1khz. beam current stability80w: within 0.1% of set value after 1/2 hour warm-up at constant output setting of 30-160kv and line voltage of 90-125 & 180-264vac.320w & 640w: same as 80w except line voltage of 180-264vac. filament supply:constant current dc filament supply withclosed-loop current feedback.filament voltage:7v rms (high frequency) max.filament current:5a max., adjustable 0-5.0a by externalfilament limit programming input. floating grid power supply:grid supply:the grid supply controls tube beam currentin a closed-loop regulation design.grid voltage:0 to 1200vdc.grid voltage ripple:less than 1.0v rms at any frequency. dimensions:7"h x 19"w x 22"d (17.8cm x 48.3cm x 55.9cm). regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. rohs compliant options:df - dual filament at - arc tripgs - grid supply io - instant onsl - slides ss(x) - non standard slow start 160kv xrf selection table output voltage kvoutput current maoutput power wmodel (x number required) 160 0.5 80 xrf160n80 160 2.0 320 xrf160n320 160 4.0 640 xrf160n640 typical applications: analytical x-ray x-ray diffraction x-ray inspection non-destructive testing
dxb series dxb bipolar outputs in a single unit compact & lightweight models from 40kv to 320kv, 300w, 600w and 1200w universal input, power factor corrected usb, ethernet and rs-232 standard interfaces ce compliant, ul recognized industrial x-ray generators dxb series 300-1200w spellman’s new dxb series of bipolar x-ray generator modules are designed for oem applications up to 320kv (±160kv) at 1200 watts. its universal input, small package size and choice of three standard digital interfaces simplifies integrating the dxb into your x-ray analysis system. dsp based emission control circuitry provides excellent regulation of emission current, along with outstanding stability performance. (ref. 128100-001 rev. n) input voltage:power factor corrected input: 100-240vac, ±10% (90-264vac):47-63hz @ 5.7a for 300 watt units200-240vac, ±10% (180-264vac):47-63hz @ 4.8a for 600 watt units47-63hz @ 8.0a for 1200 watt units output voltage:7 models: 40kv, 60kv, 80kv, 100kv, 120kv, 140kv and 320kv output polarity: ± bipolar output, filament referenced to negative output power:3 power ranges available—300 watts, 600 watts and 1200 watts other power levels available on special order. output voltage regulation:≤0.01% of rated output voltage over specified input voltage range ≤0.01% of rated output voltage for a full load change emission current regulation:≤0.01% of rated output current over specified input voltage range≤0.01% of rated output current for a change from 30% to 100% of rated output voltagefilament is disabled when kv is <30% of full scale output ripple:≤1%rms at >20 khz, 0.1%rms below 20 khzstability:≤25ppm/hr after a 2 hour warm uptemperature coefficient:≤50ppm per degree c filament configuration: closed loop emission control regulates filament setting to provide desired x-ray tube emission current.floating filament (ac output referenced to negative output voltage).output0-5 amps at a compliance of 10 volts, maximum cooling:forced air weight: 40-140kv: 26 pounds (11.8kg)320kv: 150 pounds (68kg) dimensions:40-140kv:4.75˝ h x 12˝ w x 12˝ d (120.65mm x 304.8mm x 304.8mm)320kv:10.5˝ h x 19.0˝ w x 21.5˝ d (266.7mm x 482.6mm x 546.1mm) regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. ul/cul recognized, file e227588. rohs compliant. dxb320pn1200 is not ul recognized. dxb selection table— 300w, 600w, 1200w 300 watt600 watt1200 watt kvmamodelmamodelmamodel 40 7.50 dxb40pn300 15.0 dxb40pn600 30.0 dxb40pn1200 50 5.00 dxb60pn300 10.0 dxb60pn600 20.0 dxb60pn1200 80 3.75 dxb80pn300 7.50 dxb80pn600 15.0 dxb80pn1200 100 3.00 dxb100pn300 6.00 dxb100pn600 12.0 dxb100pn1200 120 2.50 dxb120pn300 5.00 dxb120pn600 10.0 dxb120pn1200 140 2.14 dxb140pn300 4.28 dxb140pn600 8.57 dxb140pn1200 320 not available not available 3.75 dxb320pn1200 typical applications: plastics sorting crystal inspection plating measurement thickness gauging food inspection mineral analysis x-ray fluorescence x-ray diffraction cargo screening
dxm series dxm models from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable usb, ethernet and rs-232 standard interfaces ce compliant, ul recognized and rohs compliant user programmable ramping and arc detect feature dxm series 300-1200w industrial high voltage x-ray generators spellman’s new dxm series of x-ray generator modules are designed for oem applications up to 75kv at 1200 watts. its universal input, small package size and choice of three standard digital interfaces simplifies integrating the dxm into your x-ray analysis system. models are available to operate either floating filament (negative hv polarity) or ground referenced filament (positive hv polarity), x-ray tube designs. dsp based emission control circuitry provides excellent regulation of emission current, along with outstanding stability performance. (ref. 128034-001 rev. ag) input voltage:power factor corrected input100-240vac ±10% (90-264vac):47-63hz @ 4.6a for 300 watt units200-240vac ±10% (180-264vac):47-63hz @ 4.3a for 600 watt units47-63hz @ 8.2a for 1200 watt units output voltage:8 models—20kv, 30kv, 40kv, 50kv, 60kv, 70kv, 75kv and 160kv output polarity:negative- for floating filament x-ray tubespositive- for ground referenced filament x-ray tubes weight:300/600 watts: 14 pounds (6.35kg)1200 watts: 26 pounds (11.8kg) 160kv: 142 pounds (66.4kg) power:3 power ranges available:300 watts, 600 watts and 1200 watts.other power levels available on special order. output voltage regulation:≤0.01% of rated output voltage over specified input voltage range ≤0.01% of rated output voltage for a full load change emission current regulation:≤0.01% of rated output current over specified input voltage range≤0.01% of rated output current for a change from 30% to 100% of rated output voltagefilament is disabled when kv is <30% of full scale output ripple:≤1%rms at >20khz, 0.1%rms below 20khz stability:≤25ppm/hr after a 2 hour warm up temperature coefficient:≤50ppm per degree c dimensions:300/600 watts: 4.75. h x 6. w x 12. d (120.65mm x 152.4mm x 304.8mm)1200 watts: 4.75. h x 12. w x 12. d (120.65mm x 304.8mm x 304.8mm)160kv: 10.5˝ h x 19˝ w x 21.5˝ d(266.7mm x 482.6mm x 546.1mm) cooling:forced air regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. ul/cul recognized, file e227588. rohs compliant. dxm selection table— 300w, 600w, 1200w 300 watt600 watt1200 watt kvmamodelmamodelmamodel 20 15 dxm20*300 30 dxm20*600 60 dxm20*1200 30 10 dxm30*300 20 dxm30*600 40 dxm30*1200 40 7.5 dxm40*300 15 dxm40*600 30 dxm40*1200 50 6 dxm50*300 12 dxm50*600 24 dxm50*1200 60 5 dxm60*300 10 dxm60*600 20 dxm60*1200 70 4.28 dxm70*300 8.56 dxm70*600 17.12 dxm70*1200 75 4 dxm75*300 8 dxm75*600 16 dxm75*1200 160 7.5 dxm160n1200 *specify “p” for positive polarity or “n” for negative polarity typical applications: plastics sorting crystal inspection plating measurement diamond inspection mineral analysis x-ray fluorescence x-ray diffraction
dxm sub system dxm ss tube, generator, hv cable(s), cooler... fully integrated and tested at spellman high voltage assembly ready; “plug and play” out of the box cables, hoses, fittings all part of the packaged system one purchase order one phone call to spellman for support 2 year warranty for system exceeds that of individual outsourced components/assemblies. x-ray tube warranty is prorated. system matched, integrated, tested, and warrantied... all from one source spellman’s dxm series sub systems are specifically designed for low power ndt imaging applications such as food process inspection, pharmaceutical manufacture and packaging and electronic component inspection to name a few. the dxm x-ray sub systems and dxm high voltage power suppliesset the standard for compact 0.3kw to 1.2kw high performance x-ray inspection requirements. with an output voltage of 160kv, one of our dxm160 turn-key sub systems shown here. performance. low ripple... high stabilityindustry best stability and output ripple specification provide consistent output (kv & ma) for longer scans, reduced banding and improves data quality. fast ramp up time specificationsramp time is user adjustable throughthe proprietary dxm gui control. filament configurationclosed loop emission control regulates filament setting to provide desired x-ray tube emission current. either a floating filament or ground referenced filament available. reliablility. design validationindustry leading reliability and mtbf. environmental stress screening,electrical overstress, extended arcing and halt compliance. testing conducted on x-ray tube loads and beta testing in multiple applications. encapsulationthe dxm’s oil free design eliminates leaks and environmental concerns.the encapsulated dielectric high voltage section made of our proprietary large-pour formulation provides significantly higher dielectric strength than oil, is more forgiving of field stresses, and eliminates the maintenance and biohazards associated with oil tanks. flexibility. compact & lightweightthe dxm series small footprint and lightweight offer additional flexibility and logistical options. plug-n-play compatibility & ease of usedspbased smt control circuitry provides your choice of usb, ethernet and rs-232 along with analog interfaces simplifying oem system integration. serviceabilitythe dxm series has a unique modular design, with four field-replaceable units (frus) that minimize mttr, serviceinventory and overall repair cycle time.global technical support ensures swift response to any service requests. let us configure a custom dxm sub system for your application dxm x-ray generators from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable ce compliant, ul recognized and rohs compliant user programmable arc detect feature metal ceramic x-ray tubes from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable ce compliant, ul recognized and rohs compliant user programmable arc detect feature industrial x-ray tube cooler from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable ce compliant, ul recognized and rohs compliant user programmable arc detect feature hv x-ray cables from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable ce compliant, ul recognized and rohs compliant user programmable arc detect feature optional gui control software from 20kv-160kv, 300w, 600w and 1200w universal input, power factor corrected hot anode or hot cathode x-ray tube capable ce compliant, ul recognized and rohs compliant user programmable arc detect feature
xlf series xlf output voltages to 60kv integrated floating filament supply; "hot cathode" negative polarity local & remote programming 600-1200w industrial x-ray generators spellman’s xlf series of x-ray generators are well regulated high voltage power supplies with output voltages to 60kv and very low ripple achieved through the use of advanced resonant conversion techniques. extremely stable voltage and emission current outputs result in significant performance improvements over previously available technology. the xlf series provides power, control and support functions required for x-ray applications including a regulated ac filament supply referenced to the cathode. these units also incorporate local and remote programming, monitoring, safety interlock, short-circuit and overload protection. (ref. 128011-001 rev. n) input voltage:xlf 600w:115vac ±10% @ 11.4a, 50-60hz single phase220vac ±10% @ 5.9a, 50-60hz single phasexlf 1200w:220vac ±10% @ 11.8a, 50-60hz single phase filament:12 volts @ 5 amps, preheat level is 0.45 amps in standby voltage regulation:load:0.005% of full output voltage no load to full loadline:0.005% for input voltage range change current regulation:load:0.05% of full current ±100µa from 0 to full voltageline:0.05% of rated current over specified input range ripple:0.03% rms below 1khz0.75% rms above 1khz temperature coefficient:100ppm/°c. stability:0.01%/8 hrs after 1/2 hour warm-up0.02% per 8 hours (typical) cooling:fan cooled dimensions:3.5”h x 19”w x 20”d (8.9cm x 48.3cm x 50.8cm) regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. rohs compliant options:apt - adjustable power tripat - arc tripss(x) - non-standard slow startnss - no slow startio - instant onsl - slides 600w, 1200w xlf selection table 600 watt1200 watt kv ma model kv ma model 30 20 xlf30n600 30 40 xlf30n1200 40 15 xlf40n600 40 30 xlf40n1200 50 12 xlf50n600 50 24 xlf50n1200 60 10 xlf60n600 60 20 xlf60n1200 typical applications: analytical x-ray x-ray diffraction plastic sorting crystal inspection diamond inspection
dxm100 dxm100 output of 100kv at up to 1200w compact & lightweight modular unit universal input, power factor corrected usb, ethernet and rs-232 standard interfaces user programmable ramping and arc detect feature ce compliant 1200w industrial x-ray generators spellman’s new dxm100 x-ray generator module is designed for oem applications up to 100kv at 1200 watts. its universal input, small package size and choice of three standard digital interfaces simplifies integrating the dxm100 into your x-ray analysis system. dsp based emission control circuitry provides excellent regulation of emission current, along with outstanding stability. (ref. 128107-001 rev. j) input voltage:power factor corrected input, ≥ 0.98 180-264vac, 47-63hz, 8.25a maximum cooling:forced air dimensions:6.25. h x 12. w x 15.5. d (158.75mm x 304.79mm x 393.7mm) regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. ul/cul recognized, file e227588. rohs compliant. typical applications: ndt analysis plating measurement mineral analysis crystal inspection diamond inspection food/product inspection
xrv series 160kv, 225kv, 320kv, 350kv and 450kv models complete x-ray generator package power factor corrected ac input circuitry integrated dual filament supplies digital interface—usb, ethernet and rs-232 excellent stability and regulation available with black powder coated finish configure your xrv sub-system 1.8 - 6kw industrial x-ray generators spellman’s xrv series of x-ray high voltage power supplies sets the standard for compact 1.8kw to 6.0kw, high performance x-ray inspection generators. spanning an output voltage range of 160kv to 450kv in negative, positive or bipolar output configurations, there’s a model available for virtually every application requirement. active power factor correction circuitry reduces input current requirements while minimizing line related emi. spellman’s proprietary inverter topology allows for unprecedented efficiencies and power densities. a solid encapsulated high voltage section further reduces size and weight and provides reliable, maintenance free operation. dsp based smt control circuitry provides your choice of usb, ethernet and rs-232 along with analog interfacing, simplifying oem system integration. the two dc output, current regulated filament power supplies are controlled via sophisticated emission current regulation circuitry to provide accurate and stable x-ray tube currents. comprehensive fault diagnostic circuitry, and arc sense, arc quench and arc count functionality is also incorporated into this compact, space saving x-ray generator. (ref. 128060-001 rev. ae) input voltage: 1.8kw, 3.0kw, 4.0kw and 4.5kw models:180-264vac, single phase, 47-63 hertz, activepower factor corrected input to ≥0.98 6.0kw models:208 or 400vac, ±10%, three phase, 47-63 hertz, passive power factor corrected input current: 1.8kw, 3.0kw, 4.0kw and 4.5kw models:<30 amps 6.0kw models:<25 amps per phase output voltage: accuracy:0.25% stability:≤0.1% per 8 hours, after 1 hour warm up 1.8kw, 3.0kw, 4.0kw and 4.5kw models: load:±0.05% of rated output voltage for a full load change line:±0.05% of rated output voltage over specified input voltage range 6.0kw models: load:±0.1% of rated output voltage for a full load change line:±0.1% of rated output voltage over specified input voltage range output polarity:see “model selection†table output current:see “model selection†table ripple:see “model selection†table temperature coefficient: 1.8kw, 3.0kw, 4.0kw and 4.5kw models:50ppm/°c 6.0kw models:±50ppm/°c emission current: accuracy:0.25% stability:100ppm/°c 1.8kw, 3.0kw, 4.0kw and 4.5kw models: load:±0.05% of rated output current for a change from 30% to 100% of rated output voltage line:±0.05% of rated output current over specified input voltage range 6.0kw models: load:±0.1% of rated output current for a change from 30% to 100% of rated output voltage line:±0.1% of rated output current over specified input voltage range filament: output:0-6 amps at a compliance of 10vdc, maximum dual focal spot:small and large, selectable via interface signal configuration:dc filament drive. closed loop emission control regulates filament setting to provide desired x-ray tube emission current control interface: remote interface:analog, usb, ethernet and rs-232 are standard control software:a windows graphical user interface example is provided.environmentaltemperature range: operating:0°c to +50°c storage:-40°c to +85°c humidity:20% to 85% rh, non-condensing mains input connector: 1.8kw, 3.0kw, 4.0kw and 4.5kw models:type 97-3102a-24-11p 6.0kw models:type 97-3102a-24-22p interface connectors:digital—ethernet, rs-232 and usbanalog—25 pin connector output connector:see “model selection†table cooling:forced air regulatory approvals:compliant to eec emc directive/compliant to eec low voltage directive. file e227588. rohs compliant.xrv160/320/350 specificationsxrv225/450 specificationsunits are available in positive output polarity without filament, see model selection table for ordering details.*specify “p†for positive or “n†for negative polarity.**order shv hv cable flange p/n 407141-024 if using comet hv cable with r28sl spring loaded plug.j1 hv connector—r24/r28
xrvss series xrvss tube, generator, hv cable(s), cooler, controller & i/o fully tested together at spellman high voltage assembly ready “plug and play” out of the box 2 year warranty for system; prorated x-ray tube warranty configure your xrv sub-system xrv sub-systems when it comes to dependable hv power for x-ray applications, spellman high voltage leads the way. no other manufacturer builds a more reliable, efficient, stable, or compact x-ray generator. offering negative, positive or bipolar output ranging from 160kv to 450kv, spellman can deliver an ideal solution for a wide variety of applications. today’s x-ray applications demand greater performance, higher reliability, and increased flexibility. spellman has responded with the compact, powerful, and reliable xrv series. consider the benefits of the groundbreaking xrv: low ripple and active power factor correction result in reduced banding and higher quality images; an encapsulated high-voltage section cuts size and reduces weight, enabling the unit to operate oil-free and with little or no maintenance; an innovative, proprietary inverter topology allows for very high efficiency and power density, thus enhancing the overall performance of your equipment. combine spellman’s xrv series generator with the industry’s best x-ray tubes and accessories and the result is an x-ray sub system second to none. applications: ndt/inspection medical sterilization/irradiation analytical x-ray medical x-ray ate security cargo scanning digital radiography (dr) industrial ct computed radiography (cr) features: adjustable arc count, quenching and ramping speeds protect x-ray tubes lightweight compact packaging specialized warmup programs optimize tube performance and extend life tube database for all standard x-ray tubes is included with the xrv controller the use of terminal blocks for installation offer quick set-up and replacement times dual filament power supplies drive all conventional metal ceramic x-ray tubes reliability: design validation – industry leading reliability and mtbf. environmental stress screening, electrical overstress, extended arcing and halt compliance. testing conducted on x-ray tube loads and beta testing in multiple applications. encapsulation – the xrv’s oil free design eliminates leaks and environmental concerns. the encapsulated dielectric high voltage section – made of our proprietary large-pour formulation – provides significantly higher dielectric strength than oil, is more forgiving of field stresses, and eliminates the maintenance and biohazards associated with oil tanks. safety and compliance – complies with international regulatory requirements for ce/ul/csa. performance: output stability and ripple – industry best stability and lowest output ripple provide superior image quality. fast ramp up time – ramp time is adjustable from100ms to 30 seconds through the proprietary xrv gui control. fast digital controller – the xrv utilizes a dsp based microcontroller to monitor and control critical tube and generator parameters. helps ensure accuracy, repeatability, and dose stability. flexibility: small size & low cost of ownership - xrv series models measure and weigh far less than their industry counterparts. plug-n-play compatibility & ease of use – xrv comes with industry standard and custom digital and analog interfaces, including: rs-232, usb; ethernet. an intuitive windows-based gui facilitates set-up, provides diagnostics and control of status, configuration and operation. serviceability - the xrv series has a unique modular design, with four field-replaceable units (frus) that minimize mttr, service inventory and overall repair cycle time. a trouble-shooting tree and fault indicators simplify problem detection for faster, more accurate servicing. and, of course, spellman’s technical support is global, ensuring swift worldwide coverage. xrv controller with its’ one-shot profiles, intuitive touch-centric menu and interface flexibility, this powerful controller is the perfect match for your system. 7˝ touch screen lcd 10/100/1000mbit ethernet unlimited storage and recall of x-ray tube profiles complete x-ray tube database auto and customizable tube seasoning profiles bench and rack mount available xrv system interface box power distribution for system components safety interlocks for doors and tube cooler rack, bench or wall mount ip65 enclosure meets requirements of 21 cfr 1020.40 industrial x-ray tube chillers and coolers x-ray tube coolers and chillers from industry-leading manufacturers are designed and validated to work with standard metal ceramic x-ray tube offerings closed loop x-ray tube coolers for water and oil closed loop x-ray tube chillers for water and oil when ambient temperature rises to 40⁰c coolers available with ww or ow options metal ceramic x-ray tubes full range of metal ceramic tubes from industry leading manufacturers water cooled unipolar designs offered in 100, 160 and 225kv configurations oil cooled bipolar designs offered in 320, 350 and 450kv configurations available in a variety of power levels, focal spots and target angles standard and custom hv x-ray cables available in custom lengths from industry leading manufacturers straight and right angle connections available standard or spring loaded connections available gui control software for xrv the gui is specifically designed for controlling xrv series power supplies. as an alternative to the analog control, the gui will allow the user to control all necessary functions of the hvps from a user-friendly windows based menu. additionally the gui can be used as a diagnostic tool when the hvps is controlled via the analog interface. automatic x-ray tube warm-up max watts operation timed or continuous exposure modes configuration menu for user options fault and status monitor easy set up and integration
df/ff series df/ff ideal for common xrd & xrf x-ray tubes designed for common xrd & xrf x-ray tubes compact size, 5 1/4” (3u) high chassis solid encapsulation ensures maintenance-free operation auto ramp of the hv emission current to preset values oem customization available spellman’s df/ff series of x-ray generators feature our new inverter design which incorporates igbts for power switching and provides new levels of reliability. in addition, re-engineering of the df/ff’s internal filament power supply eliminates audio noise at normal operating levels by operating at a higher frequency. the df/ff’s utilize a sine wave current source, produced by phase shifting series resonant circuits at switching frequencies greater than 20khz to generate high voltage dc. this technique eliminates undesirable electromagnetic radiation normally associated with switching and power control regulators. the high efficiency of these units allows for air cooling in a 5 1/4” (3u) high chassis. (ref. 128001-001 rev. t) input voltage:220vac ±10%, 50 or 60 hz, single phase (three phase optional). output voltage:df3: 0 to 60kv negative polarity.ff3: 0 to 60kv positive polarity.other output voltages are available. output current:df3: 0 to 80ma.ff3: 0 to 100ma. other output currents are available. maximum output power: 3kw (4kw optional). output voltage regulation:load: 0.005% of rated output for full load changeline: 0.005% of rated output over specified input rangetemperature coefficient: 50 ppm/˚c (20 ppm/˚c optional) long term stability: 0.01%/8 hours. emission current regulation:load: 0.01% of rated output for a 10 to 60kv change line: 0.005% of rated output over specified inputs temperature coefficient: 50 ppm/˚c long term stability: 0.01%/8 hours filament voltage:df: 12vacff: 12vdc filament current:5a (up to 12a max available) ripple:0.03% rms <1khz, 0.75% rms above 1khz dimensions:51/4”(3u) h x 19“ w x 22” d (13.3cm x 48.3cm x 55.9cm). weight:90 lbs (40kg). regulatory approvals:compliant to eec emc directive. compliant to eec low voltage directive. model kv power (w)polarity df60n3 60 3000 n df60n4 60 4000 n ff60p3 60 3000 p ff60p4 60 4000 p typical applications: x-ray diffraction (xrd) x-ray fluorescence (xrf)
pmx pmx custom designed specifically for mammography applications compact space saving modular format fast rise and fall times help minimize unnecessary patient radiation exposure dual speed starter, boost/brake capability rs-232 and optional ethernet interfaces spellman’s pmx is a high performance x-ray generator designed specifically for mammography applications including ffdm and dbt. it features 2 and 3 point exposure modes as well as smart aec with a pre-exposure. the pmx is a 5kw high frequency x-ray generator integrated with a dual filament power supply, and a dual-speed x-ray tube starter. due to the pmx's superior power conversion technology and inverter design it can provide stable and accurate x-ray tube high voltage with fast rise and fall times. smooth system integration of the pmx is accomplished through the use of rs-232 and optional ethernet digital interface, pre-loaded x-ray tube parameters, easy access interlocks and i/o connections, and internal generator diagnostics. optional gui utility software is also offered to help with initial system integration. (ref. 128113-001 rev. c) input voltage:200-240vac (±10%), single phase, 50hz/60hz input current:minimum 35a service recommended for 5kw operationexternal emc filter (schaffner fn2070-36-08-36a) required to meet ce/emc specifications – not providedmains contactor – not providedcustomer is responsible for mains safety disconnection.output (tube) voltage output voltage range:20kv to 49kv polarity:positive, grounded cathode x-ray tube accuracy:2% (measured per iec60601-2-45) reproductibility:<0.5% rise time:<1ms to within 98% of the programmed voltage fall time:<10ms with a max hv cable length of 8 feet (2.4 meters) ripple:≤4% p-p output (tube) current/power:output current range:10ma to 200maoutput power:5kw @ 0.1 second loading time,300 watts maximum average power accuracy:< ±10% on exposure less than 10ms (measured per iec60601-2-45) rise time:<1ms to within 95% of the programmed ma value fall time:<10ms with a maximum hv cable length of 8 feet (2.4 meters) exposure time (loading time):maximum single exposure time:10 secondsshortest single exposure time:5ms loading time accuracy:±3% +1ms (measured per iec60601-2-45) maximum mas:600mas exposure timer:5ms-10 seconds accuracy:< ±10% (measured per iec60601-2-45) reproductibility:<0.5% filament configuration:dc filament drive:self corrected filament preheat settings with closed loop emission control and smart learning algorithmfilament output:0-6 amps at a compliance of 5.5 volts, maximum. dual speed starter:high speed (180hz) and low speed (60hz) can beconfigured via the serial interface.boost and brake capability provided. high voltage connector:60kv, claymount ca-3 type or equivalent communication interface:rs-232 standard, optional ethernet grounding point:m5 ground stud provided on chassis environmental:temperature range:operating: 10°c to 40°cstorage: -40°c to 85°chumidity: 20% to 85%rh, non-condensing. cooling:internal fan dimensions:9.47. h x 7.19. w x 13.72. d (240.5mm x 182.6mm x 348.5mm) weight:<23 pounds (10.5kg) regulatory approvals:designed to meet emc:iec 60601-1-2. ul/cul recognized file e242584. rohs compliant. application features:2 point/3 point exposure modesaec/smart aec exposure modesdual speed starterx-ray tube anode heat calculatorpreloaded x-ray tube parameters and expandable x-ray tube library
vmx vmx custom designed specifically for mammography applications fast settling helps minimize patient radiation exposure dual speed starter, boost/brake capability rs-232 and optional ethernet interfaces low cost, value added, modular design spellman’s vmx redefines the standard for high performance, low cost mammography x-ray generators. the vmx was born from an integrated, high performance, value added design perspective so there’s no need to compromise critical specifications to meet ever demanding system price targets. the 40kv/5kw x-ray generator integrates a dual filament power supply and a dual speed starter. a dc current source filament power supply provides fast rise times with stable and accurate x-ray tube emission currents. the solid encapsulated high voltage output section eliminates oil concerns while reducing the effects of environmental humidity and contamination. flexibility in interfacing is provided via rs-232 and optional ethernet connectivity. the vmx supports advanced mammography application features including smart aec exposure, automatic filament calibration, tube anode heat calculator and user configurable tube library. compact, full featured,high performance, low cost. spellman’s vmx, the next generation mammography x-ray generator. (ref. 128092-001 rev. l) input voltage:200-240vac (±10%), single phase, 50hz/60hz input current:minimum 35a service recommended for 5kw operationexternal emc filter (schaffner fn2070-36-08-36a) required to meet ce/emc specifications – not provided with the generatormains contactor – not provided within the generator. customer is responsible for mains safety disconnection.output voltage output voltage range:20kv to 40kv polarity:positive, grounded cathode x-ray tube accuracy:within 1% of programmed values reproductibility:<0.5% settling time:<10ms ripple:≤1% stability:≤0.01% per 8 hours temperature coefficient:≤100ppm/°coutput current/power output current range:10ma to 200ma output power:5kw @ 0.1 second loading time maximum mas:600mas exposure timer:5ms-10 seconds accuracy:within 2% of programmed values measured after ma rises to stable dc level reproductibility:<0.5% settling time:<10ms filament configuration: dc filament drive:self corrected filament preheat settings with closed loop emission control and smart learning algorithm filament output:0-6 amps at a compliance of 5.5 volts, maximumdual speed starter :high speed (180hz) and low speed (60hz) can be configured via the serial interface.boost and brake capability provided. high voltage connector:60kv, claymount ca-3 type or equivalent optional communication interface:ethernet (rj45) grounding point:m5 ground stud provided on chassis environmental:temperature range:operating: 10°c to 40°cstorage: -40°c to 85°chumidity: 20% to 85% rh, non-condensing. cooling:convection cooled, no internal fans. forced air cooling not required dimensions:9.38. h x 6.6. w x 12. d (237.5mm x 167.6mm x 304.8mm) weight:<22 pounds (10kg regulatory approvals: compliant to emc:iec 60601-1-2. ul/cul recognized file e242584. rohs compliant. application features:2 point/3 point exposure modesaec/smart aec exposure modesautomatic filament current calibrationtube anode heat calculatoruser configurable tube library
pmx70 pmx70 compact space saving modular format fast rise/fall time minimize patient exposure high speed starter, boost/brake capability ethernet/rs-232 interfaces the pmx70 is spellman’s new high performance x-ray generator designed to power varex mammography x-ray tubes. it features a 12kw peak high frequency inverter and high voltage section complete with a smart learning filament power supply and high speed starter. state of the art power conversion technology provides stable and accurate x-ray tube high voltage with fast rise and fall times. ethernet and rs-232 interfacing provides easy system integration. preloaded x-ray tube parameters, easy access interlocks and i/o connections, and internal generator diagnostics. optional gui utility software is also offered to help with initial system integration. (ref. 128113-001 rev. a) input voltage:230va c ±10%, single phase, 50hz/60hz input current:30 amps, customer to fuse.mains contactor – not provided.customer is responsible for mains safety disconnection. less than 30 amps over a typical scan is defined as following:due to unknown line impeadance, customer supllied external inductors 100uh to 300uh in series with input connections, (200uh to 600uh total), may be required to keep rms currents below 30 amps and to avoid erroneous circuit breaker trips. spellman can recommend appropriate inductors as required.output (tube) voltage output voltage range:25kv to -70kv polarity:negative output polarity; to drive rotating anode, floating cathode x-ray tube (varex m-1581). accuracy:2% (measured per iec60601-2-45) reproductibility:<0.5%output (tube) current/power output current range:10ma to 200ma output power:12kw peak, 400 watt average. duty cycle:25%. a typical scan being at fixed settings in the range of 40kv- 70kv and 16ma-200ma. pulsed operation is supported. accuracy:< ±10% on exposure less than 10ms (measured per iec60601-2-45) rise time:1-2 milliseconds, typical (hv cable dependent). fall time is load dependant, and the hv cable is a significant factor. the hv cable which is not provided with the pmx70, has a maximum length of 8 feet (2.4m). fall time:<10ms with a hv cable length of 8 feet (2.4 meters) exposure time (loading time):maximum single exposure time:20 secondsshortest single exposure time:4ms loading time accuracy:±3% +1ms (measured per iec60601-2-45) maximum mas:3200mas exposure timer:4ms-20 seconds reproductibility:<0.5% filament configuration:ac high frequency filament drive:self-corrected filament preheat settings with closed loop emissioncontrol and smart learning algorithm.filament output:0-6 amps at a compliance of 5.5 volts, maximum. high speed starter:high speed (360hz) starter configured via the serial interface. boost and brake capability provided. ac input connector:two position terminal block system interface connector:25 pin male d connector rotor interface connector:four position terminal block tube and interlock interface connector:16 pin terminal block high voltage connector:claymount ca-11 type or equivalent. communication interface connector:ethernet, rj45 jack grounding point:m5 ground stud provided on chassis environmental:temperature range:operating: 10°c to 40°cstorage: -40°c to 85°chumidity: 20% to 85%rh, non-condensing. cooling:forced air, internal fan dimensions:10.08˝ h x 19.49˝ w x 10.75˝ d (256mm x 495mm x 273mm) weight:48.5 pounds (22.0kg) rotational capability:capable of working on a rotating gantry with a nominal rotating speed of 0.5 hertz. regulatory approvals:designed to comply with iec 60601. rohs compliant.customer provided external emc filter may be required to meet ce/emc specifications. x-ray tube compatability:varex m-1581
ct - value series ct - value * ask about our subsystem capabilities 32kw / 42kw / 50kw models with same dimensions and interface for ultimate flexibility compact gantry mounting saves space, time and weight 16/32 slice with 0.5 rotation covering all clinical needs optional grid box for deflection or cut off provide dose control and improves image quality integrated fully programmable starter compatible with all industry standard x-ray tubes spellman high voltage has been designing, manufacturing and providing ct generators for oem customers for over three decades. we have unrivaled experience being the first provider of a ct generator used in a commercially available continuous rotating ct scanner in 1985. since then spellman has enhanced performance and developed new ct generators year after year, setting the standard for ct generator technology. spellman high voltage has manufactured over 30,000 ct generators. we have the knowledge, capability and experience to provide you with the ct generator technology you need. model designation:cct70pn32 cct70pn42 cct70pn50 input power:400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power:220/230vac, 1ø, +15%/-10%, 50/60hz kv output range:60kv - 140kv (bipolar, 30kv - 70kv) kv output accuracy:±0.5% of setting ma output range:10ma - 350ma, 42kw maximum ma regulation/accuracy:2% or 2ma, whichever is larger, for 20ma - 350ma filament output:2 outputs: 15vac @ 0-6a, up to 8a available filament accuracy:±5% of setting filament repeatability:±0.2% starter:hss configured to match x-ray tube used interface:custom serial interface rotation:up to 120 rpm configuration:single chassis grid option:n/a magnetic z deflection option:n/a modelct - valuect - performancect - premium 32/42/50kw 50/80kw 110 kw model designation cct70pn32 cct70pn42 cct70pn50 ct70pn50 ct70pn80 ct140n110 input power 400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power 220/230vac, 1ø+15%/-10%, 50/60hz 220/230vac, 1ø+15%/-10%, 50/60hz not required kv output range 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kvanode grounded kv output accuracy ±0.5% of setting ma output range 10ma – 350ma,42kw maximum 10ma – 420ma / 50kw maximum10ma – 667ma / 80kw maximum 6ma to 900ma,110kw maximum ma regulation/accuracy 2% or 2ma or which iser for 20ma -350ma 2% or 1ma or which islarger for 20ma -420ma 2% or 1ma or which islarger for 20ma -900ma filament output 2 outputs: 15vac @ 0-6aup to 8a available 1 output: 15vac @ 0-6a,up to 15a available 1 output: 10vac @ 0-8a, filament accuracy ±5% of setting ±5% of setting ±2% from 25% to 75%, 5% above filament repeatability ±0.2% starter hss configured to matchx-ray tube used interface custom serial interface rotation up to 120 rpm up to 120 rpm up to 240 rpm configuration single chassis two chassis four chassis grid option n/a dual grid/single filament, 0-4kv @ 0-4khz n/a magnetic zdeflection option n/a ground based single channel beam steering n/a
z series z series 450khz output frequency specially designed for dr systems simple integration via sdk to any workstation automatic calibration service-friendly design *note: all specifications are subject to change without notice. please consult the english pdf version of this datasheet for the most up-to-date revision. z series high frequency medical x-ray generators spellman, the world’s leader in high voltage innovation introduces the all new z series of high frequency, diagnostic imaging generators. these highly compact and reliable radiographic generators feature the medical industry’s highest output frequency at 450khz and world-class performance specifications, spanning 32kw to 80kw. and best of all, spellman’s engineering team will support your oem integration from beginning to end, for seamless and smooth market launch. compatible with most digital interfaces and x-ray room system mechanics, the z series is the intelligent choice for the medical oem seeking the latest technology and world-class support. radiographic options interface for automatic exposure control interface for dose measuring devices dual speed starter single console integration to your dr software specifications (ref. 128126-001 rev g) from our high performance z series to our powerful hfe series*spellman has an imaging solution to meet your unique imaging requirements z series mosfet inverter technology platform: fixed card and cable harness design industry leading output frequency (450 khz) reduced ripple for superior image quality hfe series igbt inverter technology platform: modular card and backplane design high speed ethernet communications port fluoroscopy available *please visit our website or contact sales@spellmanhv.com for more information and specifications for our hfe series spellman... your single source for imaging solutions for over 75 years, spellman high voltage has been the leader in high voltage innovation. we offer an extensive portfolio of x-ray generators and monoblock® integrated x-ray sources for diverse applications such as ct, dr, mammography, bone densitometry, surgical c-arms, and dental imaging. please consult factory regarding product configuration availability and regulatory requirements for specific markets. power level32 kw40 kw50 kw65 kw80 kw input power voltage 3ø/380/400/480 vac input power voltage 3ø/208/220/230 vac input power voltage 1ø/208/230 vac maximum output frequency 450khz tube voltage range 40~150kv tube voltage accuracy ±(5%+1kv) tube current range 10~400ma 10~500ma 10~630ma 10~800ma 10~1000ma tube current accuracy ±(10%+1ma) mas range 0.1~500mas 0.1~1000mas exposure time range 1.0~10000 ms coefficient of linearity ≤ 0.05 coefficient of reproducibility ≤ 0.05 operating modes selection kv/ma/ms, kv/mas, aec, apr anode rotation drive low speed / dual speed starter communication port rs-232 tube calibration automatic aec interface optional dap interface optional
hfe series hfe 40 – 80 kw radiographic and fluoroscopic modes of operation integrated to the most sophisticated x-ray tubes and digital workstations ethernet connections provide hfe the fastest and most stable x-ray generator communication in the market the easiest x-ray generator in the market to calibrate, service and upgrade high frequency x-ray generators for radiography and fluoroscopy quality & reliability: with a growing, global install base of thousands per year, the hfe generator boasts a feature rich, modular design for simplified serviceability and support serviceability: designed for ease of serviceability and use, the hfe contains isolated circuit breakers, allowing service engineers to power down sections of the generator at a time, improving trouble shooting while ensuring safety subsystems solutions: our powered by spellman initiative allows customers to purchase additional x-ray components from today’s leading oem manufacturers through spellman as a bundled solution, with the option of having the components pre-tested and pre-staged in our medical iso 60601 facility radiography the hfe radiographic series x-ray generators combine market leading reliability and performance, backed by our international sales, support and parts depots. radiographic generator options: consoles: - single console integration available with the today’s most commonly used dr systems, spellman provides a dr interface board, a mini console and hand switch- radiographic membrane console available for analog, or non-integrated solutions interface for automatic exposure control interface for dose measuring devices and workstations offering integrated readouts supporting all stator types high speed starter flexible cabinet options to meet your space requirements input power options: 1 φ and 3 φ configurations available output power options: 40 kw, 50 kw, 65 kw, 80 kw fluoroscopic mode used in today’s most sophisticated applications, the hfe x-ray generator for fluoroscopy offers customers a powerful engine for peak performance, driven by an intuitive service and calibration gui to operate your remote or conventional r&f x-ray room typical applications: remote r&f classical r&f urology vascular imaging molecular imaging image guided radiation therapy fluoroscopic generator options: consoles: - supporting single console integration to today’s market leading workstation providers- fluoroscopic membrane console available for non-integrated solutions continuous fluoroscopy pulsed fluoroscopy high level fluoroscopy automatic brightness stabilization powering 1 tube and 2 tube configurations supporting all stator types high speed starter input power options: supporting 3 φ configurations output power options: 40 kw, 50 kw, 65 kw, 80 kw typical applications: general radiography digital radiography tomography image guided radiation therapy
ct generator - performance series ct - performance * ask about our subsystem capabilities 50kw or 80kw in same package 64 slice with 0.5s rotation covering all clinical needs integrated deflection or cut off grid for dose control and improved image quality integrated fully programmable starter optional anode end grounded version compatible with all industry standard xray tubes performance x-ray generators for rotating ct scanner applications spellman high voltage has been designing, manufacturing and providing ct generators for oem customers for over three decades. we have unrivaled experience being the first provider of a ct generator used in a commercially available continuous rotating ct scanner in 1985. since then spellman has enhanced performance and developed new ct generators year after year, setting the standard for ct generator technology. spellman high voltage has manufactured over 30,000 ct generators. we have the knowledge, capability and experience to provide you with the ct generator technology you need. specifications (ref. 128125-001 rev. b) model designation:ct70pn50 ct70pn80 input power:400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power:220/230vac, 1ø, +15%/-10%, 50/60hz kv output range:60kv - 140kv (bipolar, 30kv - 70kv) kv output accuracy:±0.5% of setting ma output range:10ma - 420ma / 50kw maximum10ma - 667ma / 80kw maximum ma regulation/accuracy:2% or 1ma, whichever is larger, for 20ma - 420ma filament output:1 output: 15vac @ 0-6a, up to 15a available filament accuracy:±5% of setting filament repeatability:±0.2% starter:hss configured to match x-ray tube used interface:custom serial interface rotation:up to 120 rpm configuration:two chassis grid option:dual grid/single filament, 0-4kv @ 0-4khz magnetic z deflection option:ground based single channel beam steering modelct - valuect - performancect - premium 32/42/50kw 50/80kw 110 kw model designation cct70pn32 cct70pn42 cct70pn50 ct70pn50 ct70pn80 ct140n110 input power 400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power 220/230vac, 1ø+15%/-10%, 50/60hz 220/230vac, 1ø+15%/-10%, 50/60hz not required kv output range 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kvanode grounded kv output accuracy ±0.5% of setting ma output range 10ma – 350ma,42kw maximum 10ma – 420ma / 50kw maximum10ma – 667ma / 80kw maximum 6ma to 900ma,110kw maximum ma regulation/accuracy 2% or 2ma or which iser for 20ma -350ma 2% or 1ma or which islarger for 20ma -420ma 2% or 1ma or which islarger for 20ma -900ma filament output 2 outputs: 15vac @ 0-6aup to 8a available 1 output: 15vac @ 0-6a,up to 15a available 1 output: 10vac @ 0-8a, filament accuracy ±5% of setting ±5% of setting ±2% from 25% to 75%, 5% above filament repeatability ±0.2% starter hss configured to matchx-ray tube used interface custom serial interface rotation up to 120 rpm up to 120 rpm up to 240 rpm configuration single chassis two chassis four chassis grid option n/a dual grid/single filament, 0-4kv @ 0-4khz n/a magnetic zdeflection option n/a ground based single channel beam steering n/a
ct - premium series ct - premium * ask about our subsystem capabilities 110kw 128+ slice with <0.25s rotation to handle even the most demanding clinical applications sub ms rise and fall times to support spectral imaging and dual energy integrated multi-function grids for deflection, focus and cut off to control dose and provide the best image quality bi-polar or anode end grounded solutions compatible with all industry standard x-ray tubes including flat emitter technology premium x-ray generators for rotating ct scanner applications spellman high voltage has been designing, manufacturing and providing ct generators for oem customers for over three decades. we have unrivaled experience being the first provider of a ct generator used in a commercially available continuous rotating ct scanner in 1985. since then spellman has enhanced performance and developed new ct generators year after year, setting the standard for ct generator technology. spellman high voltage has manufactured over 30,000 ct generators. we have the knowledge, capability and experience to provide you with the ct generator technology you need. model designation: ct140n110 input power: 400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power: not required kv output range: 60kv - 140kv anode grounded kv output accuracy: ±0.5% of setting ma output range: 6ma to 900ma, 110kw maximum ma regulation/accuracy: 2% or 1ma, whichever is larger, for 20ma - 900ma filament output: 1 output: 10vac @ 0-8a filament accuracy: ±2% from 25% to 75%, 5% above filament repeatability: ±0.2% starter: hss configured to match x-ray tube used interface: custom serial interface rotation: up to 240 rpm configuration: four chassis grid option: n/a magnetic z deflection option: n/a modelct - valuect - performancect - premium 32/42/50kw 50/80kw 110 kw model designation cct70pn32 cct70pn42 cct70pn50 ct70pn50 ct70pn80 ct140n110 input power 400vac, 3ø, +15%/-20%, 50/60hz auxiliary input power 220/230vac, 1ø+15%/-10%, 50/60hz 220/230vac, 1ø+15%/-10%, 50/60hz not required kv output range 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kv(bipolar, 30kv – 70kv) 60kv - 140kvanode grounded kv output accuracy ±0.5% of setting ma output range 10ma – 350ma,42kw maximum 10ma – 420ma / 50kw maximum10ma – 667ma / 80kw maximum 6ma to 900ma,110kw maximum ma regulation/accuracy 2% or 2ma or which iser for 20ma -350ma 2% or 1ma or which islarger for 20ma -420ma 2% or 1ma or which islarger for 20ma -900ma filament output 2 outputs: 15vac @ 0-6aup to 8a available 1 output: 15vac @ 0-6a,up to 15a available 1 output: 10vac @ 0-8a, filament accuracy ±5% of setting ±5% of setting ±2% from 25% to 75%, 5% above filament repeatability ±0.2% starter hss configured to matchx-ray tube used interface custom serial interface rotation up to 120 rpm up to 120 rpm up to 240 rpm configuration single chassis two chassis four chassis grid option n/a dual grid/single filament, 0-4kv @ 0-4khz n/a magnetic zdeflection option n/a ground based single channel beam steering n/a