XLG Series

  • Output Voltages to 130kV
  • Ground Referenced Filament Supply
  • “Hot Anode”, Positve Polarity
  • Local & Remote Programming

Certifications & Compliance

Get a Quote

Spellman’s XLG Series of X-Ray generators are well regulated high voltage power supplies with output voltages to 130kV and very low ripple achieved through the use of advanced resonant conversion techniques. Extremely stable voltage and emission current outputs result in significant performance improvements over previously available technology.

The XLG Series provides all the power, control and support functions required for X-Ray applications including a regulated dc filament supply. These units incorporate local and remote programming, monitoring, safety interlock, short-circuit and overload protection. 

  • Specifications
  • Models
  • How to Order

Specifications

(Ref. 128012-001 REV. M)

  • Input Voltage:
    115Vac±10%, 50-60Hz single phase or
    220Vac±10%, 50-60Hz single phase.
  • Filament:
    Specify at time of order:
    FH: 
    9A, 3V.
    FL: 
    3A, 3V.
    Preheat level is 0.45 amps in standby
  • Voltage Regulation:
    Load:
    0.005% of full output voltage no load to full load.
    Line:
    0.005% for input voltage range change.
  • Current Regulation:
    Load:
    0.05% of full current ±100µA from 0 to full voltage.
    Line:
    0.05% of rated current over specified input range.
  • Ripple:
    0.03% rms below 1kHz.0.75% rms above 1kHz.
  • Temperature Coefficient:
    100ppm/°C.
  • Stability:
    0.01%/8 hrs after 1/2 hour warm-up.
    0.02% per 8 hours (typical).
  • Cooling:
    Free air convection.
  • Dimensions:
    30 to 60kV: 3.5”H x 19”W x 19”D (8.9cm x 48.3cm x 48.3cm).
    80 to 130kV: 3.5”H x 19”W x 24”D (8.9cm x 48.3cm x 61.0cm).
  • Regulatory Approvals:
    Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive.

Models

XLG SELECTION TABLE 0.1mA, 0.2mA , 0.5mA

kV0.1mA0.2mA.5mA
30XLG30P3*XLG30P6*XLG30P15*
35XLG35P3.5*XLG35P7*XLG35P17.5*
40XLG40P4*XLG40P8*XLG40P20*
50XLG50P5*XLG50P10*XLG50P25*
60XLG60P6*XLG60P12*XLG60P30*
80XLG80P8*XLG80P16*XLG80P40*
100XLG100P10*XLG100P20*XLG100P50*
120XLG120P12*XLG120P24*XLG120P60*
130XLG130P13*XLG130P26*XLG130P65*

*Specify FH for High power (27W) filament, FL for Low power (9W) filament.  

XLG SELECTION TABLE 1.0mA, 2.0mA, 3.0mA

kV1.0mA2.0mA3.0mA
30XLG30P30*XLG30P60*XLG30P90*
35XLG35P35*XLG35P70*XLG35P105*
40XLG40P40*XLG40P80*XLG40P120*
50XLG50P50*XLG50P100*XLG50P150*
60XLG60P60*XLG60P120*XLG60P180*
80XLG80P80*XLG80P160*---
100XLG100P100*XLG100P200*---
120XLG120P120*XLG120P240*---
130XLG130P130*XLG130P260*---

*Specify FH for High power (27W) filament, FL for Low power (9W) filament.  

How to Order

  • OPTIONS
    APT - Adjustable Power Trip
    AT - Arc Trip
    SS(x) - Non-Standard Slow Start
    NSS - No Slow Start
    IO - Instant ON
    LL(x) - Extra Length HV Cable
    SL - Slides

Typical Applications:

  • Analytical X-Ray
  • X-Ray Fluorescence
  • Plating Measurement
  • Mineral Analysis