Back
Browse Products By:
APPLICATIONS
Back
Browse Products By Application
View All Applications

XRBD Monoblock® Series

  • Compact & Lightweight
  • Universal Input, Power Factor Corrected
  • Can be Mounted in Any Physical Orientation
  • Analog Monitoring Interface, Standard RS-232 Digital Interface and Ethernet
  • Data Logging and Firmware Controlled X-Ray Tube Seasoning
Get a Quote

100W, 210W, 350W and 500W X-Ray Source

Spellman’s XRBD Series of Monoblock® X-Ray sources are designed for OEM applications powering their internal bipolar X-Ray tube at 160kV at power levels of 100W,210W, 350W and 500W. Features such as universal input, compact package size and a standard RS-232 digital interface simplify integration of any XRBD model into your X-Raysystem. Each XRBD model is available with fan shaped (standard) or cone shaped (optional) beam geometries. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

TYPICAL APPLICATIONS

Food Inspection Systems, Fill Level Confirmation Systems, Security Scanning Systems, Industrial NDT Systems, Thickness/Plating Measurement Systems

  • Specifications
  • Models
  • How to Order

Specifications

(Ref. 128132-001 REV. L)

  • Options:
    CB
    Cone Beam
    .5mm
  • Beam Filter:
    ST-TE, RA-SE, RA-TE
    See page 4 for Cable Options.
  • X-Ray Characteristics:
  • Focal Spot:
    0.8mm (IEC 336)
    0.5mm (IEC 336) optional
  • Beam Filter:
  • Ultem:
    1.50mm ±0.15mm
  • Oil:
    9.0mm ±0.25mm
  • Glass:
    1.7mm ±0.2mm
  • Be:
    0.8mm
  • Beam Geometry:
  • Fan:
    Standard. The beam angular coverage will be 80° with the beam plane perpendicular to the X-Ray tube axis and 12° wide (with a 2° tolerance)
  • Cone:
    Optional. 40° cone beam (with a 2° tolerance)
  • Input Voltage:
    100-240Vac, ±10%, 50/60 Hertz, .98 power factor
  • Input Current:
    100W @ 1.4A
    210W @ 2.8A
    350W @ 4.6A
    500W @ 6.6A
  • X-Ray Tube Voltage:
    See table. Minimum kV for emission current 35kV
  • X-Ray Tube Current:
    See table. Minimum emission current 150uA
  • X-Ray Tube Power:
    See table
  • Voltage Regulation:
  • Line:
    ±0.05% of maximum output voltage over a ±10% change of nominal input line voltage
  • Load:
    ±0.1% of maximum rated voltage for 150uA to full rated load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±2% of the programmed value
  • Voltage Risetime:
    Standard ramp time shall be <500ms from 10% to 90% of maximum rated output voltage
  • Voltage Ripple:
    0.5% peak to peak of maximum voltage for frequencies ≤1kHz
    Emission Current Parameters
  • Current Regulation:
  • Line:
    ±0.05% of rated output current over a ±10% change of nominal input line voltage
  • Load:
    ±0.1% of rated output current for a change from 50% to 100% of rated output voltage
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±2% of the programmed value
  • Current Risetime:
  • Standard:
    Ramp time shall be <500ms from 10% to 90% of maximum rated current
  • Arc Intervention:
    4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = Shutdown
  • Filament Configuration:
    Internal AC filament drive with closed loop filament emission control

Models

MODEL SELECTION TABLE

ModelMaximum VoltageMaximum CurrentMaximum Power
XRBD160PN100160kV1mA100 watts
XRBD160PN210160kV2.1mA210 watts
XRBD160PN350160kV3.5mA350 watts
XRBD160PN500160kV4mA500 watts

How to Order