Back
Browse Products By:
APPLICATIONS
Back
Browse Products By Application
View All Applications

XRB80PN320 Monoblock®

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & Lightweight
  • Can be Mounted in Any Physical Orientation
  • Standard RS-232 Digital Interface

Certifications & Compliance

Get a Quote

80kV, 320W X-Ray Source

Spellman’s XRB80PN320 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 80kV at 320W. Features like small package size and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

Typical applications:

  • X-Ray Scanning: Food Inspection
  • Fill Level Confirmation
  • Security Applications
  • Specifications
  • Downloads

Specifications

(Ref. 128091-001 REV. L)

  • X-Ray Characteristics:
  • Tube Type:
    Glass tube, Tungsten target, Be filter
  • Focal Spot Options:
    0.8mm x 0.8mm (IEC 336)
  • Beam Filter:
    5052 Al, 0.040" (±0.01")
  • Beam Geometry:
    Asymmetrical fan 80° x 10° ±2°
  • Input Voltage:
    200-264Vac, 50/60Hz, 4.0A max
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable between 40kV to 80kV
  • X-Ray Tube Current:
    0.5mA to 4mA over specified tube voltage range
  • X-Ray Tube Power:
    320W maximum continuous
  • Voltage Regulation:
  • Line:
    ±0.05% for a ±10% input line change
  • Load:
    ±0.05% for a 0.5mA to 4mA load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±2% of the programmed value
  • Voltage Risetime:
    Ramp time shall be <500ms from 10% to 90% of rated output
  • Voltage Overshoot:
    Within 5% of rated voltage in <10ms
  • Voltage Ripple:

    1% p-p of rated voltage @ 1kHz
  • Current Regulation:
  • Line:
    ±0.5% @ 50-100% V nominal over specified Line range
  • Load:
    ±0.5% @ 50-100% V nominal over specified Load range
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±2% of the programmed value
  • Current Risetime:
    <500ms from 10% to 90% of rated output
  • Arc Intervention:
    4 arcs in 10 seconds = shutdown
  • Filament Configuration:
    Internal high frequency AC filament drive with closed loop filament emission control