80kV, 320W X-Ray Source
Spellman’s XRB80PN320 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 80kV at 320W. Features like small package size and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.
Typical applications:
- X-Ray Scanning: Food Inspection
- Fill Level Confirmation
- Security Applications
- Specifications
- Downloads
Specifications
(Ref. 128091-001 REV. L)
- X-Ray Characteristics:
- Tube Type:
Glass tube, Tungsten target, Be filter - Focal Spot Options:
0.8mm x 0.8mm (IEC 336) - Beam Filter:
5052 Al, 0.040" (±0.01") - Beam Geometry:
Asymmetrical fan 80° x 10° ±2° - Input Voltage:
200-264Vac, 50/60Hz, 4.0A max - X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 40kV to 80kV - X-Ray Tube Current:
0.5mA to 4mA over specified tube voltage range - X-Ray Tube Power:
320W maximum continuous - Voltage Regulation:
- Line:
±0.05% for a ±10% input line change - Load:
±0.05% for a 0.5mA to 4mA load change - Voltage Accuracy:
Voltage measured across the X-Ray tube is within ±2% of the programmed value - Voltage Risetime:
Ramp time shall be <500ms from 10% to 90% of rated output - Voltage Overshoot:
Within 5% of rated voltage in <10ms - Voltage Ripple:
≤
1% p-p of rated voltage @ 1kHz - Current Regulation:
- Line:
±0.5% @ 50-100% V nominal over specified Line range - Load:
±0.5% @ 50-100% V nominal over specified Load range - Current Accuracy:
Current measured through the X-Ray tube is within ±2% of the programmed value - Current Risetime:
<500ms from 10% to 90% of rated output - Arc Intervention:
4 arcs in 10 seconds = shutdown - Filament Configuration:
Internal high frequency AC filament drive with closed loop filament emission control