XRB200PN400/2 Monoblock®
- 200kV and 400W
- X-Ray Tube Current: 0.5mA to 2.0mA @ 200kV
- Symmetrical fan beam of 85° X 4°, ±1%
- Power factor corrected input to 0.98
- 100Vac to 240Vac, ±10%
- Logging and Firmware Controlled X-Ray Tube Seasoning
Spellman’s XRB200PN400/2 is an integrated X-Ray source operating up to 200kV and 400W, providing OEM users a compact plug-and-play Monoblock® for critical inspection and screening applications. The unit incorporates a 15° angle stationary anode X-Ray tube offering a symmetrical fan beam of 85° X 4°. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, with industry leading dose stability and image quality. This compact model comes with standard analog and RS-232 digital control. Spellman can provide customized versions of this platform for specific OEM system requirements.
TYPICAL APPLICATIONS
Aviation Security Screening: Checked Baggage/EDS Vehicle Inspection, Cargo Inspection, General NDT
- Specifications
- Downloads
Specifications
(Ref. 128085-001 REV. B)
- X-Ray Characteristics:
- Tube Type:
Stationary Anode, tungsten target - Focal Spot:
0.8 x 0.8mm nominal (IEC60336) - Beam Filter:
Glass 2.1mm, maximum. Oil 18mm. - Beam Geometry:
Symmetrical fan of 85° X 4°, ±1% - Anode Angle:
15° - Input Voltage:
Power factor corrected input to 0.98. 100Vac to 240Vac, ±10%, 50/60 Hertz. 6 Amps, maximum - X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 100kV to 200kV - Voltage Accuracy:
The high voltage measured at the X-ray tube will be within ±1% of the selected value. - Voltage Ripple:
Ripple will be 1% of maximum rated voltage for frequencies ≤1kHz. - Voltage Regulation:
< ±0.1% for ±10% of nominal input line change
< ±0.1% for 0.5mA to 2mA load change - Voltage Overshoot:
kV overshoot will return within 5% of full voltage in less than 100ms. - Risetime:
The voltage and current risetime is controlled by a ramping circuit. Ramp time is less than 1.0 second from 10% to 90% of output voltage and current. - X-Ray Tube Current:
0.5mA to 2.0mA @ 200kV, 400 watts maximum - Current Accuracy:
<±1% of the selected value. - Current Regulation:
<0.5% at 100 - 200 kV, 0.5mA to 2.0mA - Arc Intervention:
Unit will detect a single arc but HV will not shut down. If multiple arcs occur (4 in 10 seconds) then the unit will shut down. - Filament Configuration:
Isolated high frequency AC filament drive operated in current mode with closed loop thermionic filament emission control. - Digital Interface:
The RS-232 and Ethernet interfaces allow for programming of the voltage, current and X-Ray Enable. Provides monitoring for voltage, current and oil temperature. Tolerance is 3%. - Control Software:
A demo GUI is available for engineering evaluation. - Operating Temperature:
0°C to +40°C - Storage Temperature:
-40°C to +70°C - Humidity:
10% to 95% relative humidity, non-condensing. - Cooling:
Heat exchanger with fan and oil pump. Customer provided +24Vdc @ 3A is required. In certain situations, external cooling fans of 250CFM may be required to maintain tank/oil temperature below 55°C. - Input Line Connector:
3 pin Phoenix Contact, p/n 1829167. Mating connector provided with unit.
Downloads
Subscribe to our high voltage newsletter
Subscribe to our high voltage newsletter, published quarterly with relevant information on high voltage power supply technology and applications.