XRB160PN480/CT Monoblock®

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & Lightweight
  • Can be Mounted in Any Physical Orientation
  • Standard RS-232 Digital Interface

Certifications & Compliance

Get a Quote

Spellman’s XRB160PN480/CT Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 480W. Features like smallpackage size and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

Typical applications:

  • X-Ray Scanning: Food Inspection
  • Fill Level Confirmation
  • Security Applications
  • Specifications
  • Downloads

Specifications

(Ref. 128083-001 REV. J)

  • X-Ray Characteristics:
  • Tube Type:
    Glass tube, Tungsten target, Be filter
  • Focal Spot:
    0.8mm x 0.8mm (IEC336)
  • Beam Filter:
    1.75mm of glass, 1mm of Al, and 10mm of oil
  • Beam Geometry:
    Symmetrical fan 105° ±3° x 4° ±1°
  • Input Voltage:
  • Monoblock®:
    100-240Vac ±10%, 50/60Hz, 6.5A max
  • Heat Dissipation Unit:
    24Vdc, 3A
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable between 20kV to 160kV
  • X-Ray Tube Current:
    0.3mA to 6mA over specified tube voltage range
  • X-Ray Tube Power:
    320W continuous, 480W peak
  • Voltage Regulation:
  • Line:
    ±0.1% for a ±10% input line change of nominal input line voltage
  • Load:
    ±0.1% for a 0.3mA to 6mA load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±1% of the programmed value
  • Voltage Risetime:
    Ramp time shall be <1 second from 1% to 90% of rated output
  • Voltage Overshoot:
    Within 5% of rated voltage
  • Voltage Ripple:
    0.1% p p of rated voltage @ ≤1kHz
  • Current Regulation:
  • Line:
    ±0.5%
  • Load:
    ±0.5%
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±1% of the programmed value
  • Current Risetime:
    <1 second from 1% to 90% of rated output
  • Arc Intervention:
    4 arcs in 10 seconds = Shutdown
  • Filament Configuration:
    Internal high frequency AC filament drive with closed loop filament emission control
  • Digital Interface:
    RS-232
  • Control Software:
    A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request.
  • Interlock Signals:
    A hardware interlock functions in digital programming modes.
  • Operating Temperature:
    0°C to +40°C
  • Storage Temperature:
    -40°C to +70°C
  • Humidity:
    5% to 90% relative humidity, non-condensing
  • Cooling:
    Heat exchanger w/fan and oil pump, powered from AC
  • Input Line Connector: