HVD Series
- 100kV, 200kV and 400kV Models
- High Input Impedance
- 25ppm Temperature Coefficient
- Corona Free Operation
- 0.5% Accuracy (higher accuracies available)
Resistive Voltage Dividers
Resistive Voltage Dividers
...for the measurement of high voltages using a standard digital voltmeter*
Spellman's HVD Series of high voltage dividers provide laboratory or production facilities with a convenient method of measuring up to 100kVdc, 200kVdc or 400kVdc with accuracy better than 0.5%. These dividers are designed for use with high impedance digital voltmeters. All HVD dividers are housed in a polycarbonate cylinder containing a matched set of precision metal film resistors which have a temperature coefficient of less than 25 ppm. A ladder-type construction technique is used in conjunction with polished high voltage bushings specifically designed to minimize corona. BNC connectors are used to provide the low voltage proportional output signal.
The HVD Series of high voltage dividers have no inferred bandwidth measurement capability what so ever. They are intended for DC steady state measurement only.
Custom Encapsulated OEM High Voltage Dividers
Spellman designs and manufactures a wide array of custom encapsulated high voltage dividers for OEM applications like ion beam implantation for semiconductor manufacturing. Unique HV divider sizes, shapes, mounting arrangements and terminations can be provided addressing specific custom requirements. Contact Spellman to discuss your needs with our knowledgeable sales staff.
Calibration
Spellman provides an NIST traceable calibration certificate with each HVD. A yearly recalibration cycle is recommended. Contact Spellman for calibration services.
*for use with digital voltmeter 10Gohms or higher.
- Specifications
Specifications
(Ref. 128055-001 REV. M)
HVD
| HVD100 | HVD200 | HVD400 | |
|---|---|---|---|
| Input Voltage | 0-100kVdc | 0-200kVdc | 0-400kVdc |
| Input Impedance | 1000Mohms | 2000Mohms | 4000Mohms |
| Output Impedance | 1M; 100kohms | 20kohms | 40kohms |
| Output Taps | 100V, 10V | 2V | 4V |
| Accuracy | 0.5%: (0.1% opt)1 | 0.5%: (0.25% opt)2 | 0.5% |
| Stability | 0.01%/8hrs | 0.025%/8hrs | 0.025%/8hrs |
| Temp. Coefficient | 25ppm/˚C | 25ppm/˚C | 25ppm/˚C |
| Height | 17.5" (44.5cm) | 33.5" (84.5cm) | 61" (154.94cm) |
| Weight | 6.75 lbs (3.1kg) | 12 lbs (5.5kg) | 24.45 lbs (11.8kg) |
(1) For accuracy of 0.1% specify HVD100-1
(2) For accuracy of 0.25% specify HVD200-1
Note: Due to the high input impedance requirement connecting the HVD to an oscilloscope input (1Mohms input impedance) will cause erroneous, inaccurate measurements
Subscribe to our high voltage newsletter