CT - Value Series
* Ask about our subsystem capabilities
- 32kW / 42kW / 50kW models with same dimensions and interface for ultimate flexibility
- Compact gantry mounting saves space, time and weight
- 16/32 slice with 0.5 rotation covering all clinical needs
- Optional grid box for deflection or cut off provide dose control and improves image quality
- Integrated fully programmable starter
- Compatible with all industry standard X-Ray tubes
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
Value Models | X-Ray Generators for Rotating CT Scanner Applications
Spellman High Voltage has been designing, manufacturing and providing CT generators for OEM customers for over three decades. We have unrivaled experience being the first provider of a CT generator used in a commercially available continuous rotating CT scanner in 1985. Since then Spellman has enhanced performance and developed new CT generators year after year, setting the standard for CT generator technology.
Spellman High Voltage has manufactured over 30,000 CT generators. We have the knowledge, capability and experience to provide you with the CT generator technology you need.
- 사양
- 모델
- 다운로드
사양
- Model Designation:
CCT70PN32 CCT70PN42 CCT70PN50 - Input Power:
400Vac, 3Ø, +15%/-20%, 50/60Hz - Auxiliary Input Power:
220/230Vac, 1Ø, +15%/-10%, 50/60Hz - kV Output Range:
60kV - 140kV (bipolar, 30kV - 70kV) - kV Output Accuracy:
±0.5% of setting - mA Output Range:
10mA - 350mA, 42kW maximum - mA Regulation/Accuracy:
2% or 2mA, whichever is larger, for 20mA - 350mA - Filament Output:
2 outputs: 15Vac @ 0-6A, up to 8A available - Filament Accuracy:
±5% of setting - Filament Repeatability:
±0.2% - Starter:
HSS configured to match X-Ray tube used - Interface:
Custom serial interface - Rotation:
Up to 120 rpm - Configuration:
Single Chassis - Grid Option:
n/a - Magnetic Z Deflection Option:
n/a
모델
| Model | CT - Value | CT - Performance | CT - Premium |
|---|---|---|---|
| 32/42/50kW | 50/80kW | 110 kW | |
| Model Designation | CCT70PN32 CCT70PN42 CCT70PN50 | CT70PN50 CT70PN80 | CT140N110 |
| Input Power | 400Vac, 3Ø, +15%/-20%, 50/60Hz | ||
| Auxiliary Input Power | 220/230Vac, 1Ø +15%/-10%, 50/60Hz | 220/230Vac, 1Ø +15%/-10%, 50/60Hz | Not Required |
| kV Output Range | 60kV - 140kV (bipolar, 30kV – 70kV) | 60kV - 140kV (bipolar, 30kV – 70kV) | 60kV - 140kV Anode grounded |
| kV Output Accuracy | ±0.5% of setting | ||
| mA Output Range | 10mA – 350mA, 42kW maximum | 10mA – 420mA / 50kW maximum 10mA – 667mA / 80kW maximum | 6mA to 900mA, 110kW maximum |
| mA Regulation/Accuracy | 2% or 2mA or which is | 2% or 1mA or which is larger for 20mA -420mA | 2% or 1mA or which is larger for 20mA -900mA |
| Filament Output | 2 outputs: 15Vac @ 0-6A up to 8A available | 1 output: 15Vac @ 0-6A, up to 15A available | 1 output: 10Vac @ 0-8A, |
| Filament Accuracy | ±5% of setting | ±5% of setting | ±2% from 25% to 75%, 5% above |
| Filament Repeatability | ±0.2% | ||
| Starter | HSS configured to match X-Ray tube used | ||
| Interface | Custom serial interface | ||
| Rotation | Up to 120 rpm | Up to 120 rpm | Up to 240 rpm |
| Configuration | Single Chassis | Two chassis | Four chassis |
| Grid Option | n/a | Dual grid/single filament, 0-4kV @ 0-4kHz | n/a |
| Magnetic Z Deflection Option | n/a | Ground based single channel beam steering | n/a |
다운로드
CT Generators
Spellman High Voltage has been designing, manufacturing and providing CT generators for OEM customers for over three decades.
스펠만 고전압 뉴스레터를 구독하세요
분기마다 발행되는 스펠만 고전압 뉴스레터를 구독하세요. 고전압전원장치에 대한 기술 정보와 최신 업계동향을 전달하여 드립니다.