XRB160PN480/1 Monoblock® Industrial X-Ray Generators
- Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
- Compact & Lightweight
- Power Factor Corrected with Internal EMI Filter
- Can be Mounted in Any Physical Orientation
- Analog Monitoring and Standard RS-232 Digital Interface
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
160kV, 480W X-Ray Source
Spellman’s XRB160PN480/1 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 480W. Features like power factor correction, small package size, standard analog monitoring and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.
Typical applications
- X-Ray Scanning:
- Food Inspection
- Fill Level Confirmation
- Security Applications
Specifications
(Ref. 128086-001 REV. J)
X-Ray Characteristics:
Tube Type: Glass tube, Tungsten target, Be filter
Focal Spot: 0.8mm x 0.8mm (IEC336)
Beam Filter: Curved 1mm A
Beam Geometry: Asymmetrical fan 80° x 10° ±2°
Input Voltage:
220Vac, ±10%, 50/60Hz, 6.5A max
X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 80kV to 160kV
X-Ray Tube Current:
0.25mA to 3mA over specified tube voltage range
X-Ray Tube Power:
500W, maximum continuous
Voltage Regulation:
Line: ±0.1% for a ±10% input line change of nominal input line voltage
Load: ±0.1% for a 0.25mA to 3mA load change
Voltage Accuracy:
Voltage measured across the X-Ray tube is within ±2% plus 1.785kV of the programmed value
Voltage Risetime:
Ramp time shall be =2 seconds from 10% to 90% of rated output
Voltage Overshoot:
±1% switching between 90kV to 160kV @ 0.25mA
Voltage Ripple:
≤ 0.1% of rated voltage from 10Hz to 1kHz
Current Regulation:
Line: ±0.5% @ 80-160kV, 0.25mA to 3mA
Load: ±0.5%, 0.25mA to 3mA
Current Accuracy:
Current measured through the X-Ray tube is within 2% of the programmed value
Current Risetime:
≤ 2 seconds from 10% to 90% of rated output
Arc Intervention:
4 arcs in 10 seconds = shutdown
Filament Configuration:
Internal high frequency AC filament drive with closed loop filament emission control
Analog Interface:
0 to 10Vdc ground referenced signals
Digital Interface:
RS-232 interface
Control Software:
A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request.
Interlock Signals:
A hardware interlock function is provided
Operating Temperature:
0°C to +40°C
Storage Temperature:
-20°C to +70°C
Humidity:
5% to 95% relative humidity, non-condensing
Cooling:
Heat exchanger w/fan and oil pump, powered from AC
Input Line Connector:
6 position terminal block
Analog Interface Connector:
7 pin Molex 26-60-5070
Digital Interface Connector:
9 pin D connector, female
Grounding Point:
8-32 ground stud provided on chassis
Dimensions:
20" X 22.5" X 10.75" (508mm X 572mm X 273mm)
Weight:
125lbs (56.7kg)
Orientation:
Can be mounted in any orientation.
X-Ray Leakage:
Not to be greater than 0.5mR/hr at 5cm outside the external surface
AC INPUT POWER J1 6 POSITION TERMINAL BLOCK
Pin | Signal | Parameters |
---|---|---|
1 | Line | Line |
2 | Removed | N/C |
3 | Neutral | Neutral |
4 | Removed | N/C |
5 | Spare | N/C |
6 | Spare | N/C |
ANALOG INTERFACE CONNECTOR— 7 PIN MOLEX, 0.156 CENTER
Pin | Signal | Parameters |
---|---|---|
1 | X-Ray | +12Vdc @16mA = enable X-Ray |
2 | X-Ray Return | X-Ray Return |
3 | N/C | N/C |
4 | kV Monitor Output | 0 to 1.6Vdc = 0 to 160kV |
5 | SGND | Signal Ground |
6 | mA Monitor Output | 0 to 3Vdc = 0 to 3mA |
7 | Fault | Open Collector, Open = No Fault |
RS-232 DIGITAL INTERFACE— 9 PIN MALE D CONNECTOR
Pin | Signal | Parameters |
---|---|---|
1 | N/C | No Connection |
2 | TX | Transmit Data |
3 | RX | Receive Data |
4 | N/C | No Connection |
5 | SGND | Signal Ground |
6 | N/C | No Connection |
7 | N/C | No Connection |
8 | X-Ray Enable | +12Vdc @ 16mA = Enable |
9 | N/C | No Connection |
Tables & Diagrams
DIMENSIONS: in.[mm]
TOP VIEW
SIDE VIEW
Frequently Asked Questions
Why Is Oil Insulation Used?
Do I Need to Ensure My Monoblock® Stays Cool? Why?
How Often Do I Need to Season My Monoblock® X-Ray Source? Why?
Application Notes AN-12 – The Benefit of Using a Current Source to Power X-Ray Tube Filament Circuits