SpellmanHV XLF Series 600W, 1200W X-ray Generators Rack Mount

XLF Series

  • Output Voltages to 60kV
  • Integrated Floating Filament Supply; "Hot Cathode"
  • Negative Polarity
  • Local & Remote Programming

*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.

Two Year Extended Warranty & RoHS Compliant Logos CE Marking

600-1200W Industrial X-Ray Generators

Spellman’s XLF Series of X-Ray generators are well regu­lated high voltage power supplies with output voltages to 60kV and very low ripple achieved through the use of advanced resonant conversion techniques. Extremely stable voltage and emission current outputs result in significant performance improvements over previously available technology. The XLF Series provides power, control and support functions required for X-Ray applica­tions including a regulated ac filament supply referenced to the cathode. These units also incorporate local and remote programming, monitoring, safety interlock, short-circuit and overload protection.

Typical applications:

  • Plastics Sorting
  • Crystal Inspection
  • Diamond Inspection

 

Specifications

(Ref. 128011-001 REV. N)

Input Voltage:

XLF 600W:

115Vac ±10% @ 11.4A, 50-60Hz single phase

220Vac ±10% @ 5.9A, 50-60Hz single phase

XLF 1200W:

220Vac ±10% @ 11.8A, 50-60Hz single phase

Voltage and Current Control:

Local: continuously adjustable from zero to maximum rating via a ten-turn potentiometer

Remote: 0 to +10Vdc proportional from 0 to full output

Accuracy: ±1%

Input Impedance: 10Mohm

Filament:

12 volts @ 5 amps, preheat level is 0.45 amps in standby

Voltage Regulation:

Load: 0.005% of full output voltage no load to full load

Line: 0.005% for input voltage range change

Current Regulation: 

Load: 0.05% of full current ±100µA from 0 to full voltage

Line: 0.05% of rated current over specified input range

Ripple:

0.03% rms below 1kHz 

0.75% rms above 1kHz

Temperature Coefficient:

100ppm/°C.

Stability:

0.01%/8 hrs after 1/2 hour warm-up 
0.02% per 8 hours (typical)

Cooling:

Fan cooled

Metering:

Digital voltage and current meters (3.5 digits), 1% accuracy

Voltage and Current Monitors:

0 to +10Vdc proportional to rated output

HV Output:

75kV, 3 conductor Federal Standard X-Ray connector

I/O Connectors:

25 pin D-type for control interface with mating connector provided

Dimensions:

3.5”H x 19”W x 20”D (8.9cm x 48.3cm x 50.8cm)

Regulatory Approvals:

Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. RoHS compliant

FRONT PANEL STATUS INDICATORS: 

Overvoltage             Voltage Control Mode  
Overtemperature      Current Control Mode  
Regulation Error       Interlock Open  
Arc                         Interlock Closed  
HV ON: Red            HV OFF: Green

OPTIONS

APT - Adjustable Power Trip  
AT - Arc Trip  
SS(x) - Non-Standard Slow Start  
NSS - No Slow Start  
IO - Instant ON  
SL - Slides

Electronic Component (Power Source)

XLF series is intended for installation as a component of a system. It is designed to meet CE standards, with conditions of acceptance often being: customer provided enclosure mounting, EMC filtering, and appropriate protection, and isolation devices. The XLF series is not intended to be operated by end users as a stand-alone device. The XLF series power supply can only be fully assessed when installed within a system, and as a component part within that system.

600W, 1200W XLF SELECTION TABLE

600 Watt 1200 Watt
kV mA Model kV mA Model
30 20 XLF30N600 30 40 XLF30N1200
40 15 XLF40N600 40 30 XLF40N1200
50 12 XLF50N600 50 24 XLF50N1200
60 10 XLF60N600 60 20 XLF60N1200

JB1 CONNECTOR 25 PIN

Pin Signal Signal Parameters
1 Power Supply Common Signal Ground
2 External Inhibit Ground=Inhibit, Open=HV On
3 External Interlock +15V at Open, <15mA at Closed
4 External Interlock Return Return for Interlock
5 Current Monitor 0 to 10V=0 to 100% Rated Output
6 kV Test Point 0 to 10V=0 to 100% Rated Output
7 +10V Reference +10Vdc @ 1mA Max
8 Remote Current Program In 0 to 10V=0 to 100% Rated Output
9 Local Current Program Out Front Panel Program Voltage
10 Remote Voltage Program In 0 to 10V=0 to 100% Rated Output
11 Local Voltage Program Out Front Panel Program Voltage
12 Power Monitor 0 to 10V=0 to 100% Rated Output (Optional)
13 Remote Power Program In 0 to 10V=0 to 100% Rated Output (Optional)
14 Local HV Off Out +15V at Open, <25mA at Closed Connect to HV OFF for Fp Operation
15 HV Off +15V at Open, <25mA at Closed Connect to HV OFF for Fp Operation
16 Remote HV On +15V, 10mA Max=HV Off 0=HV On, +15V, 10mA Max=HV Off
17 Remote HV Off Indicator +15V, 10mA Max=HV Off 0=HV On, +15V, 10mA Max=HV Off
18 Remote HV On Indicator 0=HV Off, +15V, 10mA Max=HV On
19 Remote Voltage Mode Open Collector 50V Max, 10mA Max On=Active
20 Remote Current Mode Open Collector 50V Max, 10mA Max On=Active
21 Remote Power Mode Open Collector 50V Max, 10mA Max On=Active
22 Remote PS Fault 0=Fault, +15V, 0.1mA Max=No Fault
23 +15V Output +15V, 100mA Max
24 Power Supply Common Signal Ground
25 Shield Return Shield Return

Tables & Diagrams