MPS20W Series
- Differential Input for Voltage Program
- Voltage and Current Controls
- Voltage and Current Monitors
- High Stability
- Ultra Low Ripple and Noise
- High Voltage Enable Control
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
Spellman MPS20W DC-DC 20W High Voltage Power Supplies
Spellman’s new MPS20W series are a family of high voltage 20 Watt modules that provide output voltages ranging from 1kV to 20kV.
The MPS20W series are high performance products designed with Spellman’s hybrid topology of linear and switch mode power conversion techniques delivering lower noise with higher efficiency. The MPS20W series produces excellent ripple and stability performance specifications from a compact footprint. Additionally the MPS20W series features, as standard, a differential amplifier input for the voltage programming signal to improve immunity from external system noise and addressing any offset issues. Alternatively the output voltage may be pre-set by an internal potentiometer. A fully featured remote user interface is provided via 15-pin D-type connector as standard. The output voltage is arc and short circuit protected and the power input has a current limiter fitted.
Spellman’s proprietary HV technology coupled with SMT circuitry results in an ultra compact and lightweight module that is available as either a positive or negative supply that is ideal for OEM applications.
Typical applications:
- Photomultiplier Tubes
- Microchannel Plate Detectors
- Scintillators
- Mass Spectrometry
- Electron and Ion Beams
- Electrostatic Lenses
- Nuclear Instruments
- Electrostatic Printing
Specifications
(Ref. 128064-001 REV. G)
Input Voltage:
+24 Vdc, ±2Vdc
Input Current:
≤ 1.5 amps
Output Voltage:
7 models available from 1kV to 10kV
Output Polarity:
Positive or negative, specify at time of order
Power:
≤ 20 watts
Voltage Regulation:
Line: ≤ 0.001% of rated output voltage over specified input voltage
Load: ≤ 0.001% of rated output voltage for full load change
Current Regulation (Vcc Option):
Line: ≤ 0.01% for 1V input voltage change under any load conditions
Load: ≤ 0.001% for 0 to full load
Ripple:
See “model selection” table
Stability:
≤ 0.01% per hour, 0.02% per 8 hours after 1.0 hour warm up period.
Temperature Coefficient:
≤ 25ppm per degree C
Environmental:
Temperature Range:
Operating: 0°C to 50°C
Storage: -35°C to 85°C
Humidity:
20% to 85% RH, non-condensing
Cooling:
Convection cooled
Dimensions:
1.31. H X 3.74. W X 5.91. D (33.5mm x 95mm x 150mm)
Weight:
1-2kV: 15.17 oz. (430g)
3-10kV: 25.76 oz. (730g)
15-20kV: 35.30 oz. (1000g)
Interface Connector:
15 pin male D connector
Output Connector:
A captive 39.4. (1 meter) long shielded HV cable is provided
Regulatory Approvals:
Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive.
MPS20W SELECTION TABLE
Model | Output Voltage | Output Current | Ripple (Vpp) |
---|---|---|---|
MPS1*20/24 | 0-1kV | 20mA | <25mV |
MPS2*20/24 | 0-2kV | 10 mA | <50mV |
MPS3*20/24 | 0-3kV | 6.67mA | <75mV |
MPS5*20/24 | 0-5kV | 4mA | <125mV |
MPS10*20/24 | 0-10kV | 2mA | <125mV |
MPS15*20/24 | 0-15kV | 1.33mA | <375mV |
MPS20*20/24 | 0-20kV | 1mA | <500mV |
*Specify “P” for positive polarity or “N” for negative polarity. Custom units available.
MPS20W ANALOG INTERFACE— 15 PIN D CONNECTOR
Pin | Signal | Signal Parameters |
---|---|---|
1 | Power/Signal Ground | Ground |
2 | +24Vdc Input | +24Vdc @ 1.5 amp maximum |
3 | Voltage Monitor Output | 0 to 10Vdc=0 to 100% Rated Output, Zout =2.2kΩ |
4 | Local Programming Potentiometer Wiper Output | Potentiometer connected to +10Vdc and Ground, 0 to 10Vdc adjustable wiper output provided |
5 | Voltage Program Input | 0 to 10Vdc=0 to 100% Rated Output, Zin=10MΩ |
6 | Voltage Program Differential Amplifier Output | 0 to 10Vdc=0 to 100% Rated Output, Zout =2.2kΩ |
7 | Voltage Program Differential Amplifier Input—Positive | 0 to 10Vdc differential between pin 7 and pin 9 = 0 to 100% of rated output, diode clamped to ground, Zin =38kΩ |
8 | Current Monitor Output | 0 to 10Vdc = 0 to 100% Rated Output, Zout =2.2kΩ |
9 | Voltage Program Differential Amplifier Input—Negative | 0 to 10Vdc differential between pin 7 and pin 9 = 0 to 100% of Rated Output, diode clamped to ground, Zin =38kΩ |
10 | No Connection | No Connection |
11 | Current Program Input | Standard: Internally connected to provide 110% fixed current limit VCC Option: 0 to 10Vdc=0 to 100% Rated Output, Zin=1MΩ |
12 | Enable Input | Low = Enable, TTL, CMOS, Open Collector Compliant |
13 | Internal Connection | No Connection |
14 | No Connection | No Connection |
15 | Analog Signal Ground | Analog Signal Ground |
Tables & Diagrams
DIMENSIONS: in.[mm]
1-10kV Unit
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
15-20kV Unit
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
Frequently Asked Questions
What Is a Safe Level of High Voltage?
Where Can I Obtain Information on High Voltage Safety Practices?
What Kind of High Voltage Connector Do You Use on Your Supplies?
What Do You Mean That the Output Side of the High Voltage Cable on Most Standard Products Is “Unterminated”?
How Should I Ground Your Supply?
Why Is Arcing an Issue for a High Voltage Power Supply?