SpellmanHV UM Series DC-DC High Voltage Power Supplies (Featured Image)

UM Series

  • 8 Voltage Ranges from 62.5V to 6kV, Fixed Negative or Positive Polarity
  • Available Output Power Increments of 4, 20 and 30 Watts
  • Voltage/Current Regulation with Automatic Crossover Control
  • Voltage and Current Monitor Signals
  • Fully Arc and Short Circuit Protected
  • Precision +5V Reference Output
  • Comprehensive Standard Interface
  • CE Listed, UL Recognized and RoHS Compliant

*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.

 Two Year Extended Warranty Logo CE RU Marking RoHs Compliant logo

DC-DC High Voltage Power Supplies

Form, Fit and Function Design:

Spellman’s UM Series of printed circuit board mountable, high voltage modules offer a form, fit and function replacement for presently available commercially made units, while providing additional features and benefits at competitive pricing. Utilizing proprietary power conversion technology and Spellman's six decades of high voltage experience, these SMT based high voltage modules provide improved performance/reliability and easier system integration at a lower cost when compared to the competition.

Advanced Power Conversion Topology:

UM converters use a proprietary zero voltage switching power conversion topology providing exceptional efficiency and inherent low noise and ripple. Radiated emissions are reduced compared to conventional switching topologies, minimizing or even eliminating the need to shield the unit from adjacent circuitry.

The high voltage output is generated using a ferrite core high voltage step up transformer which feeds the output circuitry. Units at 1kV or higher utilize an arrangement of half wave Cockcroft-Walton voltage multiplier stages to obtain the specified high voltage output, while lower voltage units use a robust rectification and filter circuit.

Due to the fixed, high frequency conversion rate the output capacitance is small resulting in minimal stored energy. Through the use of generously rated surge limiting resistors and a fast acting current loop, all units are fully arc and short circuit protected.

Control and Regulation:

The actual output voltage generated is sampled via a high impedance divider to create a voltage feedback signal. A current feedback signal is created via a current sense resistor in the low end return of the high voltage output circuitry. These two accurate ground referenced feedback signals are used to precisely regulate and control the units in addition to external monitoring purposes.

Due to the UM’s unique converter topology it can provide full current into low impedance loads or even a short circuit. Standard units limit at 103% of maximum rated output current.

Standard Interface:

The Spellman UM Series interface provides current program­ming capability and positive polarity, buffered, low output imped­ance voltage and current monitor signals (zero to +4.64Vdc equals zero to full scale rated). A voltage programming input is provided where 0 to +4.64Vdc equals 0 to 100% of rated voltage. Current programmability allows the user to set where the unit will current limit, anywhere from 0 to 100% of maximum rated current. This feature is beneficial where less than full output current is desired, like in the case of protecting a sensitive load.

The buffered low impedance voltage and current monitor signals can drive external circuitry directly, while minimizing loading and pickup effects. These features save the user the expense and implementation of external interface buffering circuitry while improving overall signal integrity. This standard interface is made available via a row of 13 pins with 0.1. pin spacing. A legacy interface (7 pins on a 0.2. spacing) that is compatible with presently available commercially made units can be provided by ordering the “L” option.

Mechanical and Environmental Considerations:

The UM Series are solid encapsulated, printed circuit board mountable, plastic cased converters measuring only 2.97. X 1.5. X 0.83. (75.4mm X 38.1mm X 21.1mm). All units are encapsulated using a silicon based potting material which is considerably lighter in weight than epoxy. Two isolated, non grounded 2-56 machine screws thread into the module to securely mount it to the printed circuit board, relieving any stress on the interface pins. Mounting plates, brackets and flanged mounting options are also available.

Regulatory Approvals:

Compliant to 2004/108/EC, the EMC Directive and Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. UL/CUL recognized, File E227588. RoHS Compliant.

사양

(Ref. 128068-001 REV. R)

Input Voltage:

12Vdc for 4W, 24Vdc for 20W and 30W

Nominal Voltage Range:

11Vdc to 30Vdc for 4W, 23Vdc to 30Vdc for 20W and 30W

Input Current: (typical)

Disabled: 30mA

No load: 90mA

Full load:

4 watt units: 0.5A

20 watt units: 1.0A

30 watt units: 1.5A

Efficiency:

80-85%, typical

Voltage Regulation:

Line: <0.01%

Load: <0.01%

Current Regulation:

Line: <0.01%

Load: <0.01%

Stability:

0.01% per 8 hours, 0.02% per day after 30 min. warmup

Accuracy:

2% on all programming and monitoring, except I Sense 10%

Temperature Coefficient: (typical)

Standard: 100ppm/°C Optional: 25ppm/°C (T Option)

Environmental:

Temperature Range:

Operating: 0°C to 65°C case temperature

Storage: -55°C to 85°C, non operational

Humidity:

10% to 90%, non-condensing.

Cooling:

Convection cooled, typical. 30 watt units operating at full power might require additional cooling to maintain case temperature below 65°C. Methods may include: forced air cooling, use of heat sink or metal case, etc. It is the user’s responsibility to maintain the case temperature below 65°C. Damage to the power supply due to inadequate cooling is considered misuse and repairs will not be covered under warranty.

Dimensions:

2.97" L X 1.49" W X 0.81" H (75.2mm X 37.9mm X 20.6mm)

Weight:

4 oz. (113g), typical

 

UM 4W SELECTION TABLE

Model Number Output V Output Current Low Freq. Ripple %Vp-p @ 1Hz-1kHz High Freq. Ripple %Vp-p @ 1kHz-1MHz Output Capacitance Arc Limiting Resistanc I Sense Scaling Full Scale Signal High Voltage Divider Resistance
UM0.062*4 0 to 62.5V 64mA 0.030 0.028 8.8μF 1.5V 0.5MΩ
UM0.125*4 0 to 125V 32mA 0.045 0.014 8.8μF 4.4Ω 2.75V 0.88MΩ
UM0.25*4 0 to 250V 16mA 0.034 0.017 2.2μF 20Ω 4.9V 1.50MΩ
UM0.5*4 0 to 500V 8mA 0.036 0.040 0.8μF 94Ω 10.1V 2.65MΩ
UM1*4 0 to 1KV 4mA 0.025 0.015 0.2μF 470Ω 10.75V 20MΩ
UM2*4 0 to 2kV 2mA 0.022 0.015 0.097μF 1.0KΩ 10.4V 30MΩ
UM4*4 0 to 4kV 1mA 0.019 0.017 0.012μF 9.4KΩ 11.1V 100MΩ
UM6*4 0 to 6kV 0.67mA 0.016 0.015 0.007μF 20KΩ 9.9V 150MΩ

UM 20W SELECTION TABLE

Model Number Output V Output Current Low Freq. Ripple %Vp-p @ 1Hz-1kHz High Freq. Ripple %Vp-p @ 1kHz-1MHz Output Capacitance Arc Limiting Resistance I Sense Scaling Full Scale Signal High Voltage Divider Resistance
UM0.062*20 0 to 62.5V 320mA 1Hz-1kHz 0.060 0.088 8.8μF 330mV 0.5MΩ
UM0.125*20 0 to 125V 160mA 0.067 0.044 8.8μF 4.4Ω 675mV 0.88MΩ
UM0.25*20 0 to 250V 80mA 0.035 0.019 2.2μF 20Ω 1.135V 1.50MΩ
UM0.5*20 0 to 500V 40mA 0.041 0.040 0.8μF 94Ω 2.25V 2.65MΩ
UM1*20 0 to 1KV 20mA 0.039 0.095 0.2μF 470Ω 4.35V 20MΩ
UM2*20 0 to 2kV 10mA 0.026 0.016 0.097μF 1.0KΩ 6.6V 30MΩ
UM4*20 0 to 4kV 5mA 0.023 0.028 0.012μF 9.4KΩ 6.65V 100MΩ
UM6*20 0 to 6kV 3.3mA 0.017 0.018 0.007μF 20KΩ 6.74V 150MΩ

UM 30W SELECTION TABLE

Model Number Output V Output Current Low Freq. Ripple %Vp-p @ 1Hz-1kHz High Freq. Ripple %Vp-p @ 1kHz-1MHz Output Capacitance Arc Limiting Resistance I Sense Scaling Full Scale Signal High Voltage Divider Resistance
UM0.062*30 0 to 62.5V 480mA 0.075 0.112 8.8μF 500mV 0.5MΩ
UM0.125*30 0 to 125V 240mA 0.075 0.056 8.8μF 4.4Ω 930mV 0.88MΩ
UM0.25*30 0 to 250V 120mA 0.055 0.031 2.2μF 20Ω 1.65V 1.50MΩ
UM0.5*30 0 to 500V 60mA 0.085 0.041 0.8μF 94Ω 3.4V 2.65MΩ
UM1*30 0 to 1KV 30mA 0.032 0.171 0.2μF 220Ω 6.5V 20MΩ
UM2*30 0 to 2kV 15mA 0.031 0.112 0.097μF 470Ω 9.85V 30MΩ
UM4*30 0 to 4kV 7.5mA 0.028 0.071 0.012μF 4.4KΩ 9.85V 100MΩ
UM6*30 0 to 6kV 5mA 0.020 0.051 0.007μF 9.4KΩ 10.0V 150MΩ

Note: Total ripple is the sum of the low frequency and high frequency ripple. Grayed text indicates Legacy interface signals.

STANDARD INTERFACE

Pin Signal Parameters
1 Power Ground Return +12Vdc or +24Vdc power return/HV return
1A Signature Resistor Unique Identifying resistor connected to ground
2 + Power Input +12Vdc or +24Vdc power input
2A N/C  
3 I Sense See I Sense text and tables
3A I Mon 0 to 4.64Vdc = 0 to 100% rated output. Zout < 10kΩ
4 Enable Input Low (<0.7V, Isink@1mA)=HV OFF,
High (open or >2V)=HV ON
4A V Mon 0 to 4.64Vdc = 0 to 100% rated output. Zout < 10kΩ
5 Signal Ground Signal Ground
5A I Pgm 0 to 4.64Vdc = 0 to 100% rated output. Zin > 47kΩ
Leave open for preset current limit @103% of rated output current
6 Remote Adjust Positive Polarity Unit:
0 to +4.64VDC = 0 to 100% rated voltage,
Zin >1MΩ
Negative Polarity Unit:
+5VDC to 0.36V = 0 to 100% rated voltage,
Zin >100kΩ
Leave open if pin 6A (VPgm) is used for programming
6A V Pgm  0 to 4.64Vdc = 0 to 100% rated voltage. Zin > 100kΩ
Leave open if pin 6 (remote adjust) is used for programming
7 +5V Reference Output +5Vdc ±0.5%, 50ppm/°C. Zout =475Ω
8 HV Ground Return HV Ground Return
9 E Out Monitor 10:1 ratio for models below 1kV, 100:1 ratio for models
1kV and above. Polarity of Voltage Monitor signal equals
polarity of unit. Accuracy is ±2%, 100ppm/°C. Calibrated
with DVM with 10MΩ input impedance
10 HV Output HV Output
11 HV Output HV Output

Grayed out signals are provided for backward legacy compatibility and their use is not required

Power Ground Return, Signal Ground and HV Ground Return are connected internally. For best performance they should not be connected externally.

LEGACY INTERFACE (L OPTION)

Pin Signal Parameters
1 Power Ground Return +12Vdc or +24Vdc power return/HV return
2 + Power Input +12Vdc or +24Vdc power input
3 I Sense See I Sense text and tables for details
4 Enable Input  Low (<0.7V, Isink@1mA)=HV OFF,
High (open or >2V)=HV ON
5 Signal Ground Signal Ground
6 Remote Adjust  Positive Polarity Unit:
0 to +4.64VDC = 0 to 100% rated voltage,
Zin >1MΩ
Negative Polarity Unit:
+5VDC to 0.36V = 0 to 100% rated voltage,
Zin >100kΩ
7 +5V Reference Output +5Vdc ±0.5%, 50ppm/°C. Zout =475Ω
8 HV Ground Return HV Ground Return
9 E Out Monitor 10:1 ratio for models below 1kV, 100:1 ratio for models
1kV and above. Polarity of Voltage Monitor signal equals
polarity of unit. Accuracy is ±2%, 100ppm/°C. Calibrated
with DVM with 10MΩ input impedance
10 HV Output HV Output
11  HV Output  HV Output 

Power Ground Return, Signal Ground and HV Ground Return are connected internally. For best performance they should not be connected externally.

테이블 및 다이어그램

Standard Interface Connections
Seventeen (17) gold plated 0.025˝ (0.64mm) square pins suitable for direct PCB mounting. See mechanical drawing for location and spacing details.

Programming and Monitor Signals
Voltage and current programming is done via positive polarity, high input impedance, 0 to 4.64Vdc signals.
Voltage and current monitors are positive polarity, buffered low output impedance 0 to 4.64Vdc signals.

I Mon
The I Mon signal is a true output current monitoring signal. All internal offsets due to feedback divider
currents have been compensated for.

Signature Resistor
A unique identifying signature resistor for each type of unit is connected from Pin 1A to ground. Details if desired are available upon request.

Legacy Interface Connections
Eleven (11) gold plated 0.025˝ (0.64mm) square pins suitable for direct PCB mounting. See mechanical drawing for location and spacing details.

I Sense Signal
The I Sense signal polarity is opposite of the output polarity of the module. This signal is protected via a transorb and provided via a series connected 47k isolation resistor. Internal HV dividers create a small, linear offset voltage on the I sense signal that can be compensated for.

Adhesive Backed Heat Sink
UM modules are provided with an uninstalled top mounted adhesive backed heat sink. Label removal is not required if the customer elects to install and use the provided heat sink.
The UM's internal power dissipation causes a case temperature rise. If the case exceeds 65°C, the unit needs external cooling (fan or heat sink). Even if the case is below 65°C, it is prudent to keep it much lower. Like a semiconductor device; the hotter it is, the shorter the life. For every 10°C reduction of temperature the lifetime will be increased by a factor of ≈2.35. The thermal resistance from internal circuitry to ambient is 8°C/watt without a heat sink (still air). This reduces to 6°C/watt with the heat sink.

Example:
Assuming ≈80% efficiency for a 20 watt UM module, the
5 watts of internal power dissipation would create a 40°C rise. Using the heat sink there would be only a 30°C rise. Ultimately it is up to the user to determine what cooling method is applicable for their application, but the general recommendation is to keep the module as cool as possible.

 

UM High Voltage Power Supply (Image 10)

 

UM OPTIONS

T Option
Low Temperature Coefficient-
The T Option offers the UM with an improved temperature coefficient. The standard voltage
feedback divider is replaced with one having a superior temperature coefficient, resulting in
a unit with 25ppm/C° (typical) temperature coefficient.

PHYSICAL INTERFACING

A Option

Adapter Board-
Spellman’s UM module can be fitted with an adapter board that will allow a drop in replacement for other commercially available modules of a physically larger size, while providing
identical functionality with superior performance.

UM Series Adapter Board

B Option
Terminal Block-
The B Option provides terminal block connections for both the customer interface and high voltage output/return. This feature can be helpful in situations where frequent wiring changes are anticipated, as in a testing or prototype environment.

UM Series B Option

SHIELDING

M Option
Mu Metal Shield-
UM modules can be fitted with an adhesive backed Mu Metal foil shield to help protect sensitive adjacent circuitry.

UM Series Mu Metal Shield

Same as standard unit.

S Option
RF Tight Shielded Can-
The S Option mounts the UM module inside of a flanged RF tight aluminum can.

UM Series RF Tight Shielding Can

CHASSIS MOUNTING

E Option
Eared Mounting Plate-
An eared mounting plate is affixed to the top surface of the UM module allowing simple chassis mounting of unit.

UM Eared Mounting Plate E2 Option 1

E2 Option
Eared Mounting Plate-
An eared mounting plate is affixed to the top surface of the UM module allowing simple chassis mounting of units ordered with the Adapter Board (A Option).

UM Eared Mounting Plate E2 Option

 

DIMENSIONS: in.[mm]

17 PIN - Standard Interface

UM High Voltage Power Supply (Image 15)

11 PIN - Standard Interface

UM High Voltage Power Supply (Image 16)

Note: There may be some restrictions on multiple option combinations. Please contact our sales department for more details.

ORDERING INFORMATION

     
Voltage 0 to 62.5Vdc 0.062
Voltage
0 to 125Vdc 0.125
Voltage
0 to 250Vdc 0.25
Voltage
0 to 500Vdc 0.5
Voltage
0 to 1000dc 1
Voltage
0 to 2000dc 2
Voltage
0 to 4000dc 4
Voltage
0 to 6000dc 6
Polarity Positive P
Polarity Negative N
Power Watts Output 
Power  Watts Output  20 
Power  Watts Output  30 

 

STANDARD UNIT ORDERING EXAMPLE

UM Standard Unit Ordering Example

OPTION ORDERING INFORMATION

OPTION  OPTION CODE 
Legacy Interface L
Low Temperature Coefficient
T
Adapter Board
A
Terminal Block
B
Mu Metal Shield
M
RF Tight Shielded Can
S
Eared Mounting Plate
E
Eared Mounting Plate/Adapter Board
E2

 

OPTION ORDERING EXAMPLE

UM Option Ordering Example

 

Frequently Asked Questions

What Is a Safe Level of High Voltage?
Where Can I Obtain Information on High Voltage Safety Practices?
How Should I Ground Your Supply?
Why Is Arcing an Issue for a High Voltage Power Supply?